Operation
8.2

Setting of the capacity / flow rate

The stepper motor technology means that both the suction stroke duration and metering
stroke duration can be set separately during operation via the stroke adjustment
(Fig. 17, Pos.1).
Fig. 18: Time distribution (t) of the suction (s) and metering stroke (p) with dosage rate settings of 100, 50 and 25%
1.
Use the 'Rotary button for stroke adjustment' (Fig. 17, 1) to set the required
capacity / flow rate.
2.
Locking mechanism for fixing the rotary button in place (Fig. 17, 2) should be
tightened using a suitable screwdriver to exclude the risk of accidental adjustment.
8.3

Setting / changeover of the viscosity

Meaning of the LED colours:
– LED - Metering mode "low" (left): Fig. 17, 4.
– Permanently on when the pump is started, colour: green (standby).
– Flashing when operated in "low" metering mode, colour: yellow.
– LED - Metering mode "high" (right): Fig. 17, 5.
– Flashing when operated in "high" metering mode, colour: yellow.
1.
Switch on the pump by pressing the 'ON/OFF button'
ð The pump stops operating, and all the LEDs go out.
2.
Reset viscosity by pressing the 'ON/OFF button'
button'
ð The corresponding LED (low = left Fig. 17, Pos. 4, high = right, Fig. 17, Pos. 5)
flashes green briefly.
3.
Switch on the pump by pressing the 'ON/OFF button'
ð The pump starts and the LED for the newly set viscosity flashes.
417102264 Rev. 6-12.2019
(Fig. 17, Pos.7) simultaneously for approx. 3 seconds.
(Fig. 17, Pos. 6) and the 'Test
54
(Fig. 17, Pos. 6).
(Fig. 17, Pos.6).