6. Connect the high-pressure hose to the high-pressure
connection.

12.2 Connecting the water hose

Establish the water supply to the WRS 200 (GEKA cou-
pling). Ensure that the mains is disconnected!.
Water hose
1
WRS 200 water connection
2
Front bar connection (option)
3
1. Connect the water hose to the WRS 200.
13
Operation
ATTENTION
Pump running dry
Damage to the device
If pressure does not build up in the device after 2 minutes
then switch the device off and proceed according to the in-
structions in the chapter "Help in case of malfunctions".
ATTENTION
Risk of damage
Always keep the doors closed when working and driving.

13.1 High-pressure cleaner

The high-pressure cleaner is operated by the hydraulic
PTO connection on the vehicle.
The burner can be switched-in for generating hot water.
High-pressure cleaner
1
Pressure control
2
Pressure gauge
3
Oil filler opening
4
1. The high-pressure cleaner is intended for use as a hot
water high-pressure cleaner for the elimination of weeds
and as a cold water high-pressure cleaner for cleaning
regions that are difficult to access.
2. The water jet is applied using a high-pressure gun with
spray lance and a corresponding nozzle attachment.
3. Weed elimination can also be performed over larger ar-
eas using an optional front bar. Contact Kärcher for
more information.

13.2 Control panel

The work temperature can be preselected at the tempera-
ture controller.
The burner does not switch on until the blower switch is
switched on.
ATTENTION
Risk of damage
Temperatures above 100 °C may only be selected when
the pressure is set to less than 32 bar.
Temperature controller
1
Burner blower on/off switch
2
Battery malfunction indicator
3
Warning light: cleaning container or fuel tank empty
4
Note
When the warning light comes on, the burner switches
off
Temperature setting 98°C
5
For fighting weeds
1. Set the temperature control to 98 °C and switch on the
blower for fighting weeds.
Switch off the blower switch immediately on completion
of work to prevent the battery from being drained.
2. For cold water high-pressure cleaning, turn the temper-
ature control all the way to the left and switch off the
blower.
13.3 Battery
The WRS 200 is equipped with an integrated battery that
is charged by an alternator.
The battery is required for starting the burner.
Battery
1
Minus terminal
2