WARNING
DO NOT USE PREPACKAGED WELDING INDUSTRY
COOLANTS.
These coolants may contain oil-based
substances which attack the plastic components in the
pump of the COOLARC-50 cooler and severely reduce
pump life. Once added to the cooler, the substances are
virtually impossible to purge from the water lines and
heat exchanger.
To avoid freeze damage and water leakage in shipment,
every COOLARC-50 unit is delivered empty with no
coolant in the system. To fill the unit, locate the plastic
reservoir fill cap (B).
NOTE: The unit can be filled only horizontal.
WARNING
UNPLUG THE COOLER BEFORE FILLING THE
RESERVOIR.
Filling:
Pour 6 liters at least of coolant into the reservoir.
WARNING
AVOID SPILLING COOLANT INTO THE FRONT
CASING OF THE UNIT.
NOTE:
DO NOT ADD MORE THAN 9 LITERS OF
COOLANT INTO THE RESERVOIR.
WARNING
AT
FIRST
STARTING
RESERVOIR FILL CAP MUST BE REMOVED FOR A
MOMENT TO AVOID GENERATE PARTIAL VACUUM
IN COOLING SYSTEM DURING FILLING (THE PUMP
MUST BE FLOODING).
The fill cap contains a pressure release air hole.
Be certain to replace the reservoir fill cap when the
reservoir is full. Operation of the COOLARC-50 cooler
without the fill cap in place can cause poor cooling
efficiency, evaporation loss of coolant, and low product
life.
Water Hoses Connection
A
FROM HEAT SOURCE (RED)
B
TO HEAT SOURCE (BLUE)
FIGURE 2:
Water Hoses Connection Diagram
English
OF
THE
COOLARC-50
Water hoses connection is made with quick water fittings
(type 21KATS09MPX) which are equipped with the
automatic outflow blockade.
Before water hoses installing to the cooler, you should
check if the water hose connectors matches to the quick
water connectors placed in the connector block on the
front of the unit. You should:
Take INLET hose (colored or tagged blue on most
hoses) and attach it into the coolant OUT line
marked
. Then take the OUTLET hose (colored
or tagged red on most hoses) and attach it into the
coolant IN line marked
BE CERTAIN THAT NO LEAKS EXIST WHEN COOLER
IS TURNED ON. A LEAK WILL DEPLETE RESERVOIR
VOLUME,
CAUSE
PERFORMANCE AND REDUCE GUN, TORCH OR
PUMP LIFE.
The following should always be observed when
operating the COOLARC-50:
Never operate the cooler with case off.
Immersion in water around electrical lines can
cause electrical shock.
Never place fingers into openings of cooler. Moving
parts can injure.
Unplug the cooler before filling the reservoir.
Never operate the cooler with the reservoir fill cap
off.
Never operate the cooler with the reservoir empty.

Operating Precautions

The following should always be observed when
operating any COOLARC-50 cooler:
Check the reservoir daily.
Keep the reservoir full especially after changing any
water lines.
Avoid placing the cooler near areas of extreme heat.
Avoid placing the cooler near a flux hopper or an
area where dust build-up is extreme.
Avoid kinking or putting sharp bends in any water
lines.
Keep all water lines clean.

Turning The System ON

After filling the reservoir and connecting the coolant
hoses to the COOLARC-50 cooler per the Installation
Sections, be certain that the power input into the unit
matches the cooler's rated input. Set correct power
supply using switch on the rear. Next plug the unit into
an electrical receptacle for start-up operation.
You will be able to hear the fan running and feel air flow
out of the back of the unit when the cooler is operating.
When first starting the unit, check all of the water lines to
insure that no water leaks are present. Water leakage
causes poor welding performance, poor cooling
performance, low welding component and pump life and
potential electrical safety hazards.
3
.
WARNING
POOR
OR
COOLING
English