Herunterladen Inhalt Inhalt Diese Seite drucken

Ports And Connections; Pump Installation; Installation; Rotation Direction - Pratissoli KF5M Serie Betriebs- Und Wartungsanleitung

Vorschau ausblenden Andere Handbücher für KF5M Serie:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 47
8

PORTS AND CONNECTIONS

The KF50M series pumps (see Fig. 4) are equipped with:
 2 "IN" inlet ports 1" 1/2 Gas.
Line connection to any of the two ports is indifferent for
proper pump functioning. The unused ports must be
hermetically closed.
 2 "OUT" outlet ports 1" Gas.
 3 service ports 1/2" Gas; usually used for the pressure
gauge.
9

PUMP INSTALLATION

9.1

Installation

The pump must be fixed horizontally using the M16x1.5
threaded support feet. Tighten the screws with a torque of
210 Nm.
The base must be perfectly flat and rigid enough as not
to allow bending or misalignment on the pump coupling
axis/transmission due to torque transmitted during operation.
The unit cannot be fixed rigidly to the floor but must
interposed with vibration dampers.
For special applications contact the Technical or Customer
Service Departments.
A lifting bracket is mounted on the pump for easy installation,
as per the figure below.
Should it be necessary to disassemble it, to avoid the entrance
of dirt in the front part of the casing, close the threaded hole
with the cap provided.
Replace the oil filling hole closing service
plug (red) positioned on the rear casing cover.
Check the correct quantity with the oil dipstick.
The oil dipstick must always be reachable,
even when the unit is assembled.
The pump shaft (PTO) must not be rigidly
connected to the drive unit.
The following types of transmission are
recommended:
Hydraulics by flange, for proper application
consult with our Technical or Customer Service
Departments.
V‑belts.
Universal joint (comply with the maximum working
Fig. 4
angles recommended by the manufacturer).
Flexible coupling.
9.2

Rotation direction

The rotation direction is indicated by an arrow located on the
casing near the drive shaft.
From a position facing the pump head, the rotation direction
will be as in Fig. 5.
LH SIDE
clockwise
9.3

Version change

The pump version is defined as right when:
Observing the pump facing the head side, the pump shaft
must have a PTO shank on the right side.
The pump version is defined as left when:
Observing the pump facing the head side, the pump shaft
must have a PTO shank on the left side.
Note. The version shown in Fig. 5 is right.
The version can only be modified by trained and
authorised personnel and carefully following the
instructions below:
1. Separate the hydraulic part from the mechanical
part as indicated in chapter 2 par. 2.2.1 of the
Repair manual.
22
RH SIDE
anticlockwise
Fig. 5

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Kf5m5bKf5m9b

Inhaltsverzeichnis