Direct action by the customer
Before calling service personnel, to avoid useless expense, check whether the machine problem corresponds to one of the cases
listed below.
PROBLEM
The coffee machine does not work and
the display (Ts) is blank.
Leaking from the filter holder rim (11).
Coffee dispensing time too short.
Coffee drips out of machine.
Loss of water under the machine.
Machine heated up, but it does not
dispense coffee.
The automatic level control devices
remain in operation.

18. Defects - Malfunctions

CAUSE
No electricity supply.
Underpan gasket dirty with coffee.
C o f f e e g r o u n d t o o c o a r s e .
Coffee too old.
Filter holes blocked or filter holder (11)
outlet hole dirty.
Coffee ground too fine.
D i s c h a r g e w e l l c l o g g e d u p .
Discharge pan hole blocked.
Water supply or water softener tap
closed. No water in system.
Same causes as above.
24 EN
English
SOLUTION
Check the electricity supply.
Check the position of the ON/OFF
switch (1).
Clean using the special brush pro-
vided.
Use a finer grind.
Use new coffee.
Clean.
Use a coarser grind.
Clean.
Clean.
Open.
Wait until water is available or call a
plumber.
Same solution as above.