Herunterladen Inhalt Inhalt Diese Seite drucken

Electrical Installation Rules; Water Installation Rules - LaCimbali M100 Gebrauch Und Installation

Vorschau ausblenden Andere Handbücher für M100:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 83
These chapters in the manual are to be used by qualified, authorized technical staff.
Prior to installation, make sure there is a circuit breaker installed with a distance between the contacts that allows for complete
disconnection when there is a category III overload and that provides protection against current leakage equal to 30 mA. The
circuit breaker must be installed on the power supply in compliance with installation rules.
If the power supply is not working properly, the machine can cause transitory voltage drops.
The electrical safety of this machine is only ensured when it is correctly connected to an efficient earthing system in compliance
with the electrical safety laws in force. This fundamental safety requirement must be verified. If in doubt, request that a qualified
electrician inspect the system. The manufacturer cannot be held responsible for any damage caused by the lack of an earthing
system on the electrical supply.
It is unadvisable to use adaptors, multiple plugs, and/or extension cords. If their use is indispensible, only use simple or multiple
adaptor plugs and extension cords that are in compliance with safety laws. Make sure these devices do not exceed the voltage
capacity marked on the simple adaptor and on extension cords, and the maximum voltage marked on the multiple adaptor.
Check that the type of connection and voltage correspond with the information on the nameplate: see illustrations chapter figure 1.
For machines with a Y connection: see illustrations chapter figure 2.
For machines with a ∆ connection: see illustrations chapter figure 3.
For machines with a single-phase connection: see illustrations chapter figure 4.
WATER REQUIREMENTS
Water used in coffee machines must be potable and suitable for human consumption (see laws and regulations in force).
Check on the machine's water inlet that:
the pH level complies with the laws in force
the chloride value is less than 100 mg/l
If the values do not fall within the limits, an appropriate water treatment device must be inserted (respecting the local laws and
compatible with the machine).
If the machine uses water with a hardness exceeding 8°F (4.5 °D), a specific maintenance plan must be implemented according
to the hardness detected and machine usage.
WARNING
Only use the supplied parts for installation. If other parts are installed, they must be new (not used) and they must be able to come
in contact with potable water suitable for human consumption (according to local laws in force).
WATER CONNECTIONS
Place the machine on a flat surface and stabilize it by adjusting and securing the feet.
Hook up the water connections as shown in the Illustrations chapter Figure 5, respecting the hygiene, water safety, and anti-
pollution laws in the country of installation.
Note: If the water pressure can rise above six bar, install a pressure reducer set at 2-3 bar. See Illustrations chapter Figure 6.
Water draining tube: place the end of the water draining tube in a drain with a siphon for inspection and cleaning.
IMPORTANT: The curves of the draining tube must NOT bend as shown in Illustrations chapter Figure 7.

3. Electrical Installation Rules

4. Water Installation Rules

4 EN
English
English

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis