Dip switch MODE
DART
INTERFACE I/O
Dip switch MODE
DIP1 = OFF
ON
DIP2 = OFF
1
2
DIP1
DIP2
DIP1 = ON
ON
1
2
DIP2 = OFF
DIP1
DIP2
ON
DIP1 = OFF
1
2
DIP2 = ON
DIP1
DIP2
ON
DIP1 = ON
1
2
DIP2 = ON
DIP1
DIP2
The operating mode depends on the particular accessory.
TABLE OF OPERATION (MODE) OF THE ACCESSORIES
OPER.
TYPE 1
PHOTOCELL RX
ON
CLOSE
KEY SWITCH
[AUTO-PP]
[PED]
INTERFACE I/O
In =
[AUTO-PP]
[PED]
Out = AUX
FLASHING
Defined
LIGHT
by Control
unit
Dip switch MODE
INDEX
OPERATION TYPE 1
OPERATION TYPE 2
OPERATION TYPE 3
OPERATION TYPE 4
OPER.
OPER.
OPER.
TYPE 2
TYPE 3
TYPE 4
ON OPEN
ON OPEN
ON STOP
+ CLOSE
[OPEN]
[AUTO-PP]
-
[CLOSE]
[STOP]
In =
In =
In =
[OPEN]
[AUTO-PP]
[AUTO-PP]
[CLOSE]
[STOP]
[PED]
Out = AUX
Out =
Out =
Indicator
Indicator
light
light
-
-
-

PHOTOCELL

RX PHOTOCELL TYPE 1 "ON CLOSE":
If the photocell is engaged on closure, it activates complete inversion
(opening) of the barrier. The photocell is not active during opening.
RX PHOTOCELL TYPE 2 "ON OPEN":
If the photocell is engaged on opening, it stops the barrier until it is
disengaged (restarts opening). The photocell is not active during closing.
RX PHOTOCELL TYPE 3 "ON OPEN+CLOSE":
If the photocell is engaged on opening, it stops the barrier until it is
disengaged (restarts opening). If engaged on closure, it activates complete
inversion (opening) of the barrier.
RX PHOTOCELL TYPE 4 "ON STOP":
If the photocell is engaged on opening or closing, it activates a permanent
stop of the barrier (also when automatic closing is enabled). A new
command is needed to restore operation of the automation.
KEY SWITCH
INDEX
CH2
KEY SWITCH TYPE 1 [AUTO-PP]\[PED]:
By selecting channel CH1 (key to the right), the AUTO-PP (open-close)
command is enabled, while by selecting channel CH2 (key to the left), the
PED (pedestrian opening) command is enabled.
KEY SWITCH TYPE 2 [OPEN]\[CLOSE]:
By selecting channel CH1 (key to the right), the OPEN (open only) command
is enabled, while by selecting channel CH2 (key to the left), the CLOSE
(close only) command is enabled.
KEY SWITCH TYPE 3 [AUTO-PP]\[STOP]:
By selecting channel CH1 (key to the right), the AUTO-PP (open-close)
command is enabled, while by selecting channel CH2 (key to the left),
the STOP (stop automation) command is enabled. After a STOP, a new
command is needed to restore operation of the automation.
Caution: The PED command acts exclusively in MASTER/SLAVE
installations (double barriers) by opening only the MASTER.
COMUNELLO ®Copyright 2015 - All right reserved