Herunterladen Inhalt Inhalt Diese Seite drucken

Manual Release; Preparation For Electrical Connections; Testing; Product Maintenance - Comunello LIMIT 500 ONE Installations- Und Gebrauchsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 50
LIMIT 600
BAR ASSEMBLY
AND SPRING CHOICE
Bar
Bar with bar cover kit
Bar with bar cover kit and led
Bar with swing down support
Bar with bar cover kit and swing down support
Bar with bar cover kit, led and swing down support
Bar with curtain
Bar with upper bar cover and curtain
Bar with upper bar cover, led and curtain
Bar with upper bar cover,
led, curtain and swing down support
Small spring AC 530
Medium spring AC 540
LIMIT 800
BAR ASSEMBLY
AND SPRING CHOICE
Bar
Bar with swing down support
Bar with joint
Medium spring AC 540
Double spring AC 550
Spring pull adjustment:
With the operator released (heading 4.4.3), bring the arm manually to
approximately the mid-point of its excursion (45°) FIG. 14 and release it.
If the arm tends to rise or fall, the spring must be adjusted, rotating it as
shown in FIG. 15.
4.4.2 LIMIT SWITCH ADJUSTMENT
The LIMIT barrier system is equipped with electromechanical limit switches
and two bumpers that damp the impact against the limit switches (FIG.
16A).
It is essential to make sure the bumpers are adjusted in such a way that the
limit switches can be operated. Make sure the limit switches trip correctly; if
necessary, adjust the actuator cams as shown in FIG. 16B
Proceed as follows to adjust the bumpers:
• Release the arm as described in heading 4.4.3
• Screw or unscrew the bumper pads on the plate as shown in FIG. 16A
• Secure the bumpers with the locknuts

4.4.3 MANUAL RELEASE

• To release the operator, so that the barrier arm can be moved by hand,
turn the key counter-clockwise and open the front hatch as shown in
FIG. 17.
5 PREPARATION FOR ELECTRICAL
CONNECTIONS
• Remove the front cover using the supplied key (Fig.4)
• Use only double insulated cables (sheathed cables) during the installation
phase for both the connections in AC voltage (230 V) and the ones in
SELV safety extreme low voltage (flashing, photocells).
• Double insulation of cables has to be maintained up to the immediate
proximity of terminals, unsheathing them exclusively in proximity of
terminals and they will have to be bonded by cable ties.
• Use only plastic raceways during the installation phase.
• Use separate raceways for the low voltage wirings (230 V) and for the
ones in SELV safety extreme low voltage.
• Safety extreme low voltage conductors have to be physically separated
(at least 4 mm up in the air) from the ones in AC voltage, or they have
to be adequately isolated with additional insulation with a thickness of at
least 1 mm.
• Use FG7 2x1,5 mm2 cables or an higher category as power cord.
• Provide upstream of the mains supply of the automation a device that
can assure an all-pole disconnection from the electrical grid (with the 3rd
category of overvoltage and with an opening distance of the contacts in
each pole of at least 3 mm), in compliance with the installation rules and
directly connected to the power supply terminals.
• Bring the wiring to the electronic circuit board located at the top of the
operator, routing the cables along the rear wall as shown in FIG. 18A and
FIG. 18B.
LENGTH (meters)
2,0 2,5 3,0 3,5 4,0 4,5 5,0 5,5 6,0
Double spring AC 550
LENGTH (meters)
6,0
6,5
7,0
7,5
8,0

6 TESTING

Perform the following sequence of operations to test the LIMIT barrier
system:
• Check that all the prescriptions in this manual have been followed
scrupulously, with special attention to chapter 1 "General Prescriptions";
• Using the supplied control or stopping devices (key selector switch,
control pushbuttons or remotes), perform opening, closing and
stopping tests and make sure the barrier responds correctly to the
various commands.
• Check operation of all the system's safety devices (photocells, safety
edges, emergency stop, etc.), one by one.

7 PRODUCT MAINTENANCE

Maintenance must be carried out at regular intervals by qualified personnel
in compliance with the provisions of statutory legislation and the regulations
in force. LIMIT undergo scheduled servicing at least once every 6 months.
• Disconnect the operator from all power supplies
• Check all the moving parts and renew any worn parts
• Check all parts of the automation system for signs of deterioration

8 SPARE PARTS

Spare parts can be purchased by contacting technical service.
9 DISPOSAL
At the end of its useful life the automation system must be dismantled by
qualified personnel and the materials must be recycled or disposed of in
compliance with the local legislation in force.
TECHNICAL SPECIFICATIONS
Buffer battery input:
Service output (Electric Lock/Flashing Light):
impulse
Operator outpu:
LED output
Operating temperature:
Radio receiver:
Transmitters op.:
Max. TX codes in memory:
Board dimensions:
BUS ACCESSORIES
Maximum number of accessories that can be connected on the BUS line:
Max n° 2 flashing lights
Max n° 6 pairs of photocells TX/RX
Max n° 2 key switches
Max n° 4 I/O interface boards
PRELIMINARY CHECKS
• Check that the product in the pack is intact and in good condition.
• Check that the place of installation is suitable and in compliance with the
minimum dimensions shown in FIG. 1.

ELECTRICAL CONNECTIONS

CN1
Buffer battery kit (AC51) connector 24V
CN2
Mains power connector 230V~ 50/60Hz
CN3
Transformer primary (mains voltage)
CN4
Transformer secondary (operator power supply)
CN5
Transformer secondary (BUS line power supply)
CN6
Layout drawing reference
MOT1 +:
Operator 1 Output (+)
MOT1-:
Operator 1 output (-)
LED+:
LED strip power output +24V
LED-:
LED strip power output -24V
OUT AUX +24V: U Utility Output (AUX Flashing light or Electric Lock)
+24V
OUT AUX -24V: Utility Output (AUX Flashing light or Electric Lock)
-24V
FC MOT1 FCC:
Operator 1 Closing Limit Switch Input (NC)
FC MOT1 GND: Operator 1 Limit Switch Common Input
FC MOT1 FCA:
Operator 1 Opening Limit Switch Input (NC)
CN7
COMUNELLO ®Copyright 2015 - All right reserved
24 V
battery kit (code no. AC51)
24 V
5W (continuous), 12W max.
150W max
50W
-20 ÷ +50 °C
433 Mhz
18 Bit or Rolling Code
400 (CODE PP, CODE PED, AUX)
170 x 107 mm.
39

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Limit 600 oneLimit 800 one

Inhaltsverzeichnis