MT
If the water level is too low, the silt in
the shaft can quickly dry out and im-
pede the pump when warming up.

Mains Connection

The pump you have purchases is already
itted with an earthed plug. The equipment
is designed for connection to an earthed
wall socket with a RCD (Residual Current
Device) at 230 V ~ 50Hz.
Connecting the Pressure
Line
The pump is installed
-
Either with a ixed pipeline
-
Or with a lexible hose line.
1. Screw the quick-connect adapter
(8) onto the pump outlet (6).
2. Press the red release button on
the quick-connect adapter (8)
and slide the angle adapter with
quick-connect connector (9) into
the quick-connect adapter (9).
Let go of the red release button
again.
3. Fit the hose over the reducer (10)
and secure it with a hose clamp.
Or use a screw connection on
the angle adapter with quick-
connect connector (9), or on the
reducer (10).
Œ
Outlet with a 1½"-internal thread
on the pump for connection of the
quick-connect adapter (8) or for
direct connection of a hose with a
1½"-external thread;

Outlet with 1½"-external thread at the
bracket adapter (9) for connection
of the reducer (10) or a 1½"-screw
connection;
36
Outlet on reducer (10) for connection
Ž
of a 1¼"- or 1½"-hose as a
compression joint (ixing with a hose
clamp);

Outlet with 1"-external thread at
the reducer (10) for connection of a
1"-screw connection;

Outlet with 1½"-thread at the reducer
(10) for connection of a 1"-hose as
clamp connection (ixing with a hose
clamp).
Note that the particle size may
be max. 19 mm if the reducer
(Ø 19.3 mm) is used, otherwise
the reducer and hose can become
blocked.
Adjustment of the loat
switch
The loat switch (
it can be started up immediately.
In the case of stationary
installation, check regularly (no less
then once every three months) that
the loat switch (
The On/Off switch point of the loat switch
7) is ininitely variable:
(
Loosen the lever (13) in the loat
switch height adjustment (2) and
move it to the desired position.
Check the loat switch (
- It must be positioned so that it
can lift and lower freely. The
switching point heights "On"
and "Off" must be easy to
reach.
Check this by placing the pump
into a vessel illed with water
3) is adjusted so that
3) is working.
3).

Quicklinks ausblenden: