Herunterladen Inhalt Inhalt Diese Seite drucken

Connection To The Power Supply - Notes For The Installer; Connection Conditions; Connecting To The Mains - hanseatic 2013C(G)3.334eETsPrDpHbJX Gebrauchsanleitung

Herd-set mit glaskeramik-kochfeld, pyrolyse und zeitschaltuhr
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

28 mm
15
(f)
6. Use the supplied retaining clamps to fix
the hob in place to prevent it from slipping.
Screw the 4 retaining clamps into the
hob from beneath and affix it in the work
surface with the help of gentle hammer
strokes.
Connection to the power
supply – notes for the installer
WARNING
Electric shock / fi re hazard!
Improperly installed electrical connec-
tions can cause electrical shocks and/or
short circuits.
Connection to the mains supply
be made only by an authorised elec-
trician
approved by the local energy
supply company, e.g. our Service de-
partment (see page EN-37). Only then
will you benefi t from our warranty
and a suffi cient level of safety.
Since all poles of the appliance can-
not be disconnected from the mains
via an accessible disconnecting de-
vice, an all-pole disconnecting device
in accordance with overvoltage cat-
egory III must be connected within
the house installation with at least
3 mm contact clearance; this includes
fuses, miniature circuit breakers and
protective devices.
(g)
may
Fitting and installation

Connection conditions

– The rated voltages allowed as well as the
rating of the device can be found in Chapter
„Technical specifications" on page EN-42.
– Depending on the type of connection al-
lowed, you must
– select the cross-section cable
– insert or remove contact bridges
(see table and circuit diagrams on the
right).
– The power cord used must comply with
the requirements of DIN EN 60335-1 (e.g.
H05RR-F model).
– A separate power supply is required.
– When connecting the appliance, VDE re-
quirements and the 'Technical connec-
tion requirements' must be observed.
Contact protection must be guaranteed.

Connecting to the mains

The terminal block and connection diagrams
can be found on the rear side of the oven.
1. Before accessing the terminals, switch off
all supply circuits and secure them against
being switched on again.
2. Make sure that all poles of the connection
cables are disconnected and that effective
earthing is possible.
3. Connect the leads and, if necessary, the
enclosed brass bridges to the correspond-
ing contact terminals of the cooker power
connection in accordance with the circuit
diagrams shown here.
4. Lay the connection cable behind the cook-
er so that it does not touch the rear wall of
the cooker. The rear cooker wall becomes
hot while it is in use.
Page EN-31

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

1110 9819