Herunterladen Inhalt Inhalt Diese Seite drucken

Specification Measurement Cables; Oscilloscope - Bosch FSA 500 Originalbetriebsanleitung

Fahrzeug-system-analyse
Vorschau ausblenden Andere Handbücher für FSA 500:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 4
en
30 | FSA 500 | Technical data
8.10.3

Specification measurement cables

Designation
Order number
Battery B+/B– cable
1 684 460 286
Clip-on sensor
1 687 225 018
Primary connection
1 684 461 185
cable,
term. 1/15
CH1 multi measurement
1 684 460 288
cable
CH2 multi measurement
1 684 460 289
cable
Amps clamp 1000 A
1 687 225 019
Amps clamp 30 A
1 687 225 020
Test prods:
1 683 050 050
Test prods
Test terminals
Secondary measuring
1 687 225 017
sensor
1 687 225 021
Oil temperature sensor
1 687 230 068
Connection at the input secondary measuring sensor
1)
1.6 Vpeak ±30% at 100 mA current change within 200 ns with connection at input clip-on sensor (L/C approx. 136 µH/5 nF)
2)
For voltages >60 V, U[V] x t[ms] ≤ 10000 V/ms applies, e.g. a voltage of 200 V can be applied no longer than 50 ms. The maximum vol-
3)
tage reduces at frequencies of >1 MHz with 20 dB/decade, e.g. sine 1 MHz maximum peak = 200 V / sine 10 MHz maximum peak = 20 V
Special accessory
4)
8.10.4

Oscilloscope

R
Trigger system
$
Free run (non-triggered run ≥ 1 s)
$
Auto (curve output even without trigger)
$
Auto-Level (as Auto, mid-signal trigger threshold)
$
Normal (manual trigger threshold, curve output
only with trigger event)
$
Single sequence
R
Trigger edge
$
Edge (pos./neg. on signal)
R
Trigger sources
$
Engine (trigger on cylinder 1.. 12 with clip-on
sensor, term. 1, KV sensor)
$
External trigger via term. 1_1 cable or clip-on
sensor
$
CH1 / CH2 multi measurement cable
R
Pre-trigger component
$
0 to 100%, adjustable with mouse
R
Recording modes
$
MaxMin (Peak/Glitchdetect)
$
Interference pulse recording
$
Sample (equidistant sampling)
R
Storage operating and curve output modes
$
Roll mode (single point output) with complete
storage of signals for X deflections ≥ 1 s
$
Legend mode (curve output) with complete sto-
rage of signals for X deflections ≥ 1 ms
$
Normal mode with storage of last 50 curves dis-
played for X deflections < 1 ms
|
1 689 989 411
2019-04-01
Measure-
Max. measuring voltage
ment
category
CAT 1
60 V DC/30 V AC/
42 V ACpeak
CAT 1
30 kV ACpeak
CAT 1
60 V DC/300 V ACpeak
CAT 1
60 V DC/200 V ACpeak
CAT 1
60 V DC/200 V ACpeak
CAT 1
300 V DC/ACrms
CAT 1
300 V DC/ACrms
4)
CAT 1
30 V DC/ACpeak
CAT 1
30 V DC/ACpeak
CAT 1
30 kV ACpeak
4)
CAT 1
5 V
R
R
R
R
R
R
Sensor output sensiti-
vity
2)
3)
3)
3)
100 mV/A
4 mV/A
20 mV/kV
1)
Resistance:
1005 Ω at 25 °C
1530 Ω at 90 °C
Quantity measurement system with 8 automatic
measurement functions
$
Mean value
$
Rms value
$
Min
$
Max
$
Peak-to-peak
$
Pulse
$
Duty cycle
$
Frequency
Selectable signal range
$
Full curve or between cursors
Zoom
$
Selectable curve section for horizontal and verti-
cal enlargement
Adjustable cursors with indicators for
$
x1, x2
$
delta x
$
y1 and y2 (channel 1)
$
y1 and y2 (channel 2)
Comparison curves
$
Store, load, comment, presetting of scope setup
for live curves
Storage functions
$
Scrolling back and forth
$
Search functions, e.g. MinMax, duty cycle
Max. output voltage
at the measurement
cable
60 V
5 V
300 V
200 V
200 V
5 V
5 V
30 V
300 V
1 V
5 V
Robert Bosch GmbH

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading