5/ Electric connections

Rules for connecting the appliance
- No electrical connections must be made in the hydraulic area.
- You must use a 230 V single-phase 50 Hz power supply.
- The appliance must be directly connected to the mains supply after the circuit breaker and with no intermediate switch.
- The appliance must be connected to the mains supply with its cable and via a connection box.
- This appliance is a class II appliance and must therefore not be connected to the earth. Do not connect the
pilot wire (black wire) to the earth.
- The installation must be equipped with an all-pole cut-off device with a contact opening distance of at least 3 mm.
- If the power cable is damaged, it must be replaced by the manufacturer, their after sales service or by a similarly qualified per-
son.
- The electric and hydraulic circuits are separate to avoid any short circuits.
- Before connecting the appliance to the mains supply, make sure the voltage is the same as the one marked on the appliance's
identification plate.
- The appliance must be connected to the mains supply in compliance with the rules in force.
Appliance's wiring diagram
Cut the power and connect the wires as shown in the following diagram:
You must comply with the Phase and Neutral connections, otherwise the fan will rotate in the wrong direction, leading
to a loud noise and bad performance.
You can connect the pilot wire if your house is equipped with a central programming unit, a timer or a manager, or if your
generator is equipped with a compatible pilot wire output.
In this case, to make sure the programming commands are correctly sent, carry out the following checks for the various
modes (Comfort, Eco, etc.) :
Mode
COMFORT
Signal to send
Measurement
between the pilot
0 Volt
wire and the
neutral
Please follow the recommendations given in your appliance's user manual for programming it.
:
Panel heater cable
Live=brown
Neutral=blue
Pilot wire=Black
1st case: only one heater
2nd case: multiple heaters
ECO
230 Volts
LIVE
NEUTRAL
Two possible cases
The pilot wire end is insulated
and not further connected
The pilot wire of all heaters in a
control group, up to a maximum
of 20 units with any one them used
as the Master, are connected
by a 1.0mm
SWITCH OFF
FREEZE
AND POWER
PROTECTION
CUT OFF
-115 Volts
+115 Volts
négative
12
Electricity
grid
2
220-240V insulated cable
COMFORT
-1°C
230 Volts
positive
for 3 s
COMFORT
-2°C
230 volts
for 7 s