Safety Instructions

Safety Instructions for Transport and Installation

2.3.1

Special safety instructions for mobile conveyor systems

§
The conveyor systems are designed only for manual transport. Transport using any kind of devices is
not permitted.
§
Conveyor systems can start moving on their own and randomly if the total brakes are not applied.
§
Switch off the conveyor system and pull out the mains plug before transporting it.
§
Never pull the mains plug out of the socket by the wire.
§
Before moving the conveyor system release the locking brakes. Moving the appliance with the applied
locking brakes can damage the chassis!
§
Do not move the appliance over inclined surfaces or stairs. When approaching walls and moving
round obstacles always pay attention to persons in the way.
§
When transporting the conveyor system, do not move it faster than a walking pace. It is difficult to
brake and steer heavily laden appliances. If necessary, ask for assistance when transporting the
appliance.
§
When moving the conveyor system make sure that the appliance will not tip over due to outside
influences or inattention. If, nevertheless, it tips over never try to catch the conveyor system.
§
Secure the conveyor system against rolling away by applying the total brakes before putting it into
operation.
§
Do not stop the appliance on sloping floors. Before placing the appliance in position make sure that
the floors are level and even and the conveyor system is level.
§
A maximum belt length of 23 ft (7 m) should not be exceeded.
2.4
Safety Instructions for Transport and Installation
The following points are to be observed when transporting the conveyor system:
§
When loading, use only hoists and load lifting devices approved for appliances 1,5 times heavier than
the appliance to be lifted.
§
Use transport vehicles that are approved for the weight of the conveyor system.
§
Use transport vehicles that are approved for the weight of the conveyor system.
§
Parts that have possibly been dismantled prior transport must be fitted back and fastened before
putting the appliance into operation.
§
Even in case of a minor relocation switch off the conveyor system at the mains or disconnect it from
any power supply.
§
In accordance with the legal regulations the buyer bears the risk of transportation. Ask the deliverer to
write down visible damages in the waybill.
§
In no case put a defective appliance into operation and inform the supplier immediately.
2.5

Safety Instructions for Maintenance and Care

The following points shall be observed when carrying out any maintenance operations:
§
Take the conveyor system out of operation, switch it off and secure against unauthorised reactivation
before performing maintaining or troubleshooting operations. When operating on the electrical
installation, the appliance is to be switched off at the mains and secured against reactivation.
§
Only persons with qualifications and knowledge of electrical engineering may perform maintenance
and repair work on electrical devices.
§
If it is required to maintain or repair live parts, you should in any case call in a second person.
§
You have to meet the deadlines for maintenance and care specified in the operating instructions.
§
Before proceeding with maintenance and repair work close the maintenance area and the access to
the working area for unauthorised persons. If necessary place an indication sign that draws attention
to the running maintenance and repair work.