Herunterladen Inhalt Inhalt Diese Seite drucken

Overview Of The Service Menu - Bosch MS 200 Installationsanleitung

Solarmodule
Vorschau ausblenden Andere Handbücher für MS 200:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
5. To complete the solar system configuration:
– Confirm the current system configuration.
Solar configuration completed...
1.
2.
3.
4.
5.
MS 200 – 6720879925 (2017/11)
ok
ok
ok
ok
4.4

Overview of the service menu

The menus depend on the installed user interface and the installed
system.
Service menu
Commissioning
– ...
Solar settings
– Solar thermal sys installed
– Change solar configuration
– Current solar configuration
– Solar parameters
– Solar circuit
– Speed ctrl. solar pump
(Solar pump 1 solar circuit speed, collector array)
– Min. speed solar pump
(Minimal speed of solar pump 1, collector array)
– Switch-on diff. solar pump
(ON temperature differential, solar pump 1 collector array)
– Switch-off diff. solar pump (Cut-out temperature differential,
solar pump 1 collector array)
– Speed ctrl solar pump2
(Solar pump 2 circuit speed, collector array)
– Min. speed solar pump 2
– Switch-on diff. sol. pump2
(ON temperature differential, solar pump 2 collector array)
– Switch-off diff. sol. pump2
(OFF temperature differential, solar pump 2 collector array)
– Max. collector temp. (Maximum collector temperature)
– Min. collector temp. (Minimum collector temperature)
– Vac. tube pump anti-seize
(Vacuum tube collector, pump anti-seize 1 collector array)
– Vac. tube pump kick 2
(Vacuum tube collectors, pump anti-seize 2 collector array)
– Southern Europe function
– Switch-on temp. S.Eur. fct.
(Switch-ON temperature Southern Europe function)
– Collector cooling function
– Cylinder
– Max. temp. cyl. 1 (Cylinder 1 maximum temperature)
– Max. temp. cyl. 2 (Cylinder 2 maximum temperature)
– Max. pool temp. (Maximum swimming pool temperature)
– Max. temp. cyl. 3 (Cylinder 3 maximum temperature)
– Priority cylinder
– Test interval priority cyl. (Test interval priority cylinder)
– Test duration priority cyl. (Test duration priority cylinder)
– Elapsed time valve cyl. 2
(Running time 3-way valve between 1st and 2nd cylinders)
– Switch-on diff. heat ex.
(Temperature differential heat exchanger)
– Switch-off diff. heat ex.
(OFF temperature differential heat exchanger)
– Frost prot. temp. heat ex. (Frost threshold heat exchanger)
– Central heating backup
– Start diff. ctrl. heat back.
(ON temperature differential for central heating backup)
– End diff. ctrl. heat. back.
(OFF temperature differential for central heating backup)
– Max. mixer temp. CH
(Max. mixer temperature for central heating backup)
Commissioning
31

Quicklinks ausblenden:

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis