TECHNICAL DATA

MODEL
TYP
OUTPUT
(1)
FUEL
- Net caloriÞc value
- Absolute density
- Max. delivery
- Pressure at maximum delivery
OPERATION
STANDARD APPLICATIONS
AMBIENT TEMPERATURE
COMBUSTION AIR TEMPERATURE
ELECTRICAL SUPPLY
ELECTRIC MOTOR
IGNITION TRANSFORMER
ELECTRICAL POWER CONSUMPTION
ELECTRICAL PROTECTION
IN CONFORMITY WITH EEC DIRECTIVES
APPROVAL
(1) Reference conditions: Ambient temperature 20 ° C - Barometric pressure 1000 mbar - Altitude 100 m a.s.l.
(2) Pressure at test point 16)(A)p.10, with zero pressure in the combustion chambre, with open gas ring 2)(B)p.18 an maximum burner output
GAS CATEGORIES
COUNTRY
SE - FI - AT - GR - DK - ES - GB - IT - IE - PT
DE
NL
FR
BE
LU

VARIANTS

Electrical supply
MODEL
three phase
230-400N
GAS 8 P/M
230-400N
230-400N
230-400N
GAS 9 P/M
400N
400N
GAS 10 P/M
400N
400N
Important:
The installer is responsible for the addition of any safety device not forseen in the present manual.
2nd stage
Mcal/h
1st stage
Mcal/h
kWh/Nm
Mcal/Nm
kg/Nm
Nm
mbar
(2)
° C max
V1 - V2
I1 - I2
kW max
Blast tube
length mm
391
501
444
574
230
444
230
574
444
574
230
476
230
606
476
606
GAS 8 P/M
538 T1
kW
1163 - 2210
1000 - 1900
kW
640 - 1163
550 - 1000
NATURAL GAS: G20 - G21 - G22 - G23 - G25
G20
G25
10
8,6
3
8,6
7,4
3
3
0,71
0,78
221
257
3
/h
15
22,2
¥ On - Off (1 stop min each 24 hours).
These burners are also Þtted for the continuous operation, if they are
equipped with the control box LANDIS type LGK 16.322 A27
(interchangeable with the burner control box Landis LFL 1.322 )
¥ Progressive two-stage or modulating by kit (see ACCESSORIES)
Boilers: water, steam, diathermic oil
° C
0 - 40
60
V
230 - 400 with neutral ~ +/- 10%
Hz
50 - three-phase
rpm
2900
kW
4
V
220 / 380
240 / 415
A
15 - 8,7
230 V - 8 kV
1,8 A - 30 mA
5
IP 40
90/396 - 89/336 - 73/23
CE
0085AP0941
CATEGORY
I
2H
I
2ELL
I
2L
I
2Er
I
2E(R)B
I
2E
Motor
Direct starting
Direct starting
Direct starting
Direct starting
Star-delta starting
Star-delta starting
Star-delta starting
Star-delta starting
Star-delta starting
Star-delta starting
Star-delta starting
Star-delta starting
6
GAS 9 P/M
GAS 10 P/M
540 T1
541 T1
1744 - 3488
2441 - 4885
1500 - 3000
2100 - 4200
870 - 1744
1140 - 2441
750 - 1500
980 - 2100
G20
G25
G20
10
8,6
10
8,6
7,4
8,6
0,71
0,78
0,71
348
406
488
13,4
19,8
21
2900
7,5
220 / 380
220 / 380
240 / 415
240 / 415
26 - 15
41,5 - 24
9
0085AP0942
0085AP0943
GB
G25
8,6
7,4
0,78
568
31
2900
12