Completely close the water supply tap (or remove the suction pipe from the tank).
Run the high-pressure cleaner for a few seconds with the lever (22) of the gun pressed to expel any
excess water.
Place the master switch (1) into position "0".
Remove the plug from the power socket.
Eliminate any residual pressure that has remained in the high-pressure pipe (35) by pressing the
lever (22) of the gun for a few seconds.
Wait for the high-pressure cleaner to cool.
Reel-up the high pressure hose (35) with care and without bending it.
Wind-up the power supply cable with care.
When using on the floor, put the high pressure water cleaner away carefully in a dry and clean place.
Make sure not to damage the power supply cable and the high pressure hose.
Carry out the operations described in paragraph "STOPPING", following the table below.
MAINTENANCE INTERVAL
On every use
Weekly
Monthly
Supplementary maintenance must be carried out by a QUALIFIED TECHNICIAN, following the
table below (guideline data).
MAINTENANCE INTERVAL
Every 50 hours
Every 100 hours
12
STOPPING
STORAGE

ROUTINE MAINTENANCE

Check the power cable, high-pressure pipe, connectors, gun and lance
pipe. If one or more parts are damaged, do not use the high-pressure
water cleaner and contact a QUALIFIED TECHNICIAN.
Cleaning of inlet water filter (18).
Unscrew the hose connector (25) O (27) and remove the filter (18).
Cleaning the filter under running water or compressed air is generally
sufficient. In more difficult cases, use a scale-removing product or replace
it by contacting an authorised assistance centre to purchase it.
Refit the filter and tighten the hose connector.
Cleaning the nozzle.
It is usually sufficient to clean the hole of the nozzle with the pin supplied
(31). If this operation fails to satisfactorily clean the nozzle, replace the
latter by ordering a spare part from an authorised service centre.
The nozzle is replaced using the key (32) (supplied).

SUPPLEMENTARY MAINTENANCE

Check the pump hydraulic circuit (water).
Check pump fixing.
Pump oil replacement.
Check pump delivery/intake valve.
Check tightness of pump screws.
Check pump control valve.
Check the safety devices.
OPERATION
OPERATION

Werbung

Inhaltsverzeichnis