Troubleshooting

5.1
Troubleshooting
The following is list of troubleshooting tips and messages that you may encounter. They include
explanations and, in some cases, a recommended action. If a problem seems unsolvable,
contact your local Siemens Ultrasonic Flow Representative for expert help at
www.automation.siemens.com/partner (http://www.automation.siemens.com/partner).
Table 5-1
Troubleshooting Tips
Message
Memory Full!
Memory Corrupted!
Chan Not Setup
Clr Active Memory?
Clr Saved Data?
<EOT>
Empty Pipe - Press <ENT>
Fill Pipe - Press <ENT>
No Sites - Press <ENT>
Invalid Setup
FUT1010 IP65 NEMA 4X & IP66 NEMA 7 Liquid Quick Start
Operating Instructions, 6/2010, A5E02639182A Revision 02
Description
Response to an attempt to save site data, when data memory is full. Delete an obsolete
site or clear Datalogger memory to make room for the new data.
Memory read error occurred while accessing the active site data.
Response to an attempt to invoke an operation that requires a channel to be enabled.
Enable the channel [Channel Setup - Channel Enable - Yes]. Note that a channel cannot
be enabled until its sensors are operating.
Response to pressing the F4 key. Use the F4 function to restore operation if a severe event
(e.g., a violent power surge) disrupts system operation.
[Clr Saved Data?] only appears after answering No to [Clr Active Memory?]. Answering Yes
to [Clr Saved Data?] will erase ALL saved data.
Response to a request to output Datalogger data to the printer or the Graphics screen when
no Datalogger data exists. Set up the Datalogger.
Prompt to empty the pipe during the Actual MTY procedure. After emptying pipe, press
<ENT>.
Prompt to fill the pipe during the Actual MTY procedure. After filling the pipe, press [ENT]
Response while trying to recall/delete a site setup when no sites are stored.
During the Initial Makeup the system detects invalid transducer spacing, erroneous liquid
pipe parameters, or some other factor that prevents it from completing the Initial Makeup.
This may be due to one of the following:
● An out-of-range data entry.
● An invalid condition (e.g., overlapping transducers in Reflect Mode).
● In Reflect Mode the flowmeter detects that the pipe wall signal may infringe upon the
signal.
● Press <ENT>, <Up Arrow>, <Down Arrow>, or <Left Arrow> to abort install routine.
Continue programming other site data in anticipation of resolving the difficulty later. Call
technical support for help, if necessary.