Herunterladen Inhalt Inhalt Diese Seite drucken

Troubleshooting/Faqs; Troubleshooting; Table 4- 1 Troubleshooting Tips - Siemens SITRANS FUH1010 Betriebsanleitung (Kompakt

Vorschau ausblenden Andere Handbücher für SITRANS FUH1010:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Troubleshooting/FAQs

4.1

Troubleshooting

The following is list of troubleshooting tips and messages that you may encounter. They
include explanations, and in some cases, a recommended action. If a problem seems
unsolvable, contact your local Siemens Ultrasonic Flow Representative for expert help
(www.siemens.com).
Table 4- 1
Troubleshooting Tips
Message
Memory Full!
Memory Corrupted!
Chan Not Setup
Clr Active Memory?
Clr Saved Data?
<EOT>
Empty Pipe - Press <ENTER>
Fill Pipe - Press <ENTER>
No Sites - Press <ENTER>
Re-space Index
SITRANS FUH1010 Quick Start
Operating Instructions (Compact), 12/2008, CQO:QSG010 Revision A
All manuals and user guides at all-guides.com
Description
Response to an attempt to save site data, when data
memory is full. Delete an obsolete site or clear Datalogger
memory to make room for the new data.
Memory read error occurred while accessing the active site
data.
Response to an attempt to invoke an operation that requires
a channel to be enabled. Enable the channel [Channel
Setup - Channel Enable - Yes]. Note that a channel cannot
be enabled until its transducers are operating.
Use this function to restore operation if a severe event (e.g.,
a violent power surge) disrupts system operation. Refer to
flowmeter manual.
Use this function to clear Dynamic Memory. Refer to
flowmeter manual.
Response to a request to output Datalogger data to the
printer or the Graphics screen when no Datalogger data
exists. Set up the Datalogger.
Prompt to empty the pipe during the Actual MTY procedure.
After emptying pipe, trigger <ENTER>.
Prompt to fill the pipe during the Actual MTY procedure.
After filling the pipe, trigger [ENTER]
Response while trying to recall/delete a site setup when no
sites are stored.
Upon measuring the liquid sonic velocity (Vs), the meter
recommends re-spacing the transducers to improve
performance.
4
35

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

7me3601-4

Inhaltsverzeichnis