Pd11 Function Table - V2 Vega-C series Bedienungsanleitung

Elektromechanisches stellglied 230v/120v für schwenktüre. digitalsteuerung eingebaut
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 55
DISPLAY
DATA
DESCRIPTION
dEF.
no
Upload default values
Si
Keeps the previous configuration (if the control unit is new, the data are the default ones)
t.AP
0.0" ÷ 2.0'
Gate opening time
t.Ch
0.0" ÷ 2.0'
Gate closing time
dir
Motor direction
nor
- Direction of the rotation of the standard motor for traditional garage doors
inv
- It reverses the direction of rotation of the motor
Pot
30 ÷ 100%
Motor power
SPUn
no / Si
Start off
t.P.So
0.5" ÷ 3.0"
Slowed down starting time
no
- Slowed down starting disabled
t.raL
0.5"÷22.5"
Slow down time
no
- Slow down disabled
St.AP
Start in opening
no
- Start command is not available
ChiU
- Command close door
PAUS
- Stop the door and goes in pause
St.Ch
Start in closing
Stop
- Start command stop the door
APEr
- Start command open the door
St.PA
Start in pause
no
- Start command is not available
ChiU
- Start command closes the door
Ch.AU
Automatic closing
no
- The door closes after the setup time)
0.5"÷ 20.0'
- The automatic closing is not active (it corresponds to 0)
Ch.tr
Closing after passage
no
- Closing after passage disabled
0.5"÷ 20.0'
- Gate stop for a time to be set between 0.5" to 20'
PA.tr
no / Si
Pause after transit
LUCI
Courtesy Light
t.LUC
- Lights start time adjustable from 0 to 20'
CiCL
- Lights are on trough the whole cycle
AUS
- Auxiliary output
tiM
- Timed aux out (from 0 to 20')
biSt
- Aux out relay with bistable functioning
Mon
- Aux out relay with monostable functioning
Strt
Operation modes
no
- Standard operation
StAn
- Start inputs from terminal board are disabled
StoP
STOP input
no
- STOP input not available
invE
- STOP command stops the door: START command starts moving in the opposite direction
ProS
- STOP command stops the door: pressing the START command door continues the motion
Foto
Photocell input
CFCh
- Photocell is active in closing and also when the door is still
no
- Not available
Ch
- Photocell is active during the closing
tESt
Test of safety devices
no
- Function not active
Foto
- Test enabled only for photocells
CoSt
- Test enabled only for safety edges
Ft.Co
- Test enabled either for photocells or for safety edges
ShAd
Photocell shadow zone
no
- Function disabled
F.ShA
- Time of end disabling
i.ShA
- Time of beginning enabling
CoSt
Border input
no
- Input disabled (the control unit ignores it)
rESi
- Input enabled for conductive rubber ribbons
StAn
- Input enabled for standard safety ribbons with normally closed contact
AP.Ch
- Input enabled in opening and closing phase
AP
- Input enabled only in opening phase
Ch
- Input enabled only in closing phase

PD11 FUNCTION TABLE

MEMO
DEFAULT
DATA
no
22.5"
23.5"
60
no
1.5"
6.0"
PAUS
StoP
ChiU
no
no
1'00
StAn
no
CHCh
no
no
no
StoP