Elektromechanisches stellglied 230v/120v für schwenktüre. digitalsteuerung eingebaut
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 55

IMPORTANT REMARKS

For any installation problem please contact our Customer
Service at the number +39-0172.812411 operating Monday to
Friday from 8:30 to 12:30 and from 14:00 to 18:00.
V2 has the right to modify the product without previous
notice; it also declines any responsibility to damage or injury
to people or things caused by improper use or wrong
installation.
Please read this instruction manual very carefully before
installing and programming your PD11 control unit.
• This instruction manual is only for qualified technicians,
who specialize in installations and automations.
• The contents of this instruction manual do not concern the
end user.
• Every programming and/or every maintenance service
should be done only by qualified technicians.
AUTOMATION MUST BE IMPLEMENTED IN COMPLIANCE
WITH THE EUROPEAN REGULATIONS IN FORCE:
EN 60204-1 (Machinery safety. electrical equipment of
machines, part 1: general rules)
EN 12445
(Safe use of automated locking devices,
test methods)
EN 12453
(Safe use of automated locking devices,
requirements)
• The installer must provide for a device (es. magnetotermical
switch) ensuring the omnipolar sectioning of the equipment
from the power supply.
The standards require a separation of the contacts
of at least 3 mm in each pole (EN 60335-1).
• After making connections on the terminal board, use one
hose clamp to fix dangerous voltage wires near the terminal
board and another hose clamp to fix safety low voltage wires
used for accessories connection; this way, in case of
accidental detachment of a conducting wire, dangerous
voltage parts will not come into contact with safety low
voltage ones.
• The plastic case has an IP55 insulation; to connect flexible
or rigid pipes, use pipefittings having the same insulation
level.
• Installation requires mechanical and electrical skills,
therefore it shall be carried out by qualified personnel only,
who can issue the Compliance Certificate concerning the
whole installation (EEC Machine Directive 89/392, Annex IIA).
• The automated vehicular gates shall comply with the
following rules: EN 12453, EN 12445, EN 12978 as well
as any local rule in force.
• Also the automation upstream electric system shall comply
with the laws and rules in force and be carried out
workmanlike.
• The door thrust force adjustment shall be measured
by means of a proper tool and adjusted according to
the max. limits, which EN 12453 allows.
• We recommend to make use of an emergency
button, to be installed by the automation (connected
to the control unit STOP input) so that the door may
be immediately stopped in case of danger.
• Always remember to connect the earth according to
current standards (EN 60335-1, EN 60204-1).

DECLARATION OF CONFORMITY

V2 ELETTRONICA SPA declares that the series of VEGA-C
actuators are in conformity with the provisions of the following
EC directives:
73/23/EEC
electrical safety
93/68/EEC
electromagnetic compatibility
99/05/EEC
radio directive
98/37/EEC
machine directive
Note: Declares that the above mentioned devices may not be
operated until the machine (automated door) is identified, CE-
labeled, and declared to be compliant to the specifications of
Directive 89/392/EEC and following modifications.
The person in charge for the machine start-up must provide the
following records:
• Technical specification paper
• Declaration of conformity
• CE-labeling
• Testing record
• Maintenance record
• Operation manual and directions
Racconigi 18/10/2006
V2 ELETTRONICA SPA legal representative
A. Livio Costamagna
TECHNICAL
SPECIFICATIONS
Power supply
Nominal power
Line absorption
Absorbed power
Full load current
Capacitor
Average speed
Working temperature
Protection
Working cycle
Motor weight
Max accessories load 24V
Protection fuse
21
VEGA230V-C
VEGA120V-C
230VAC - 50Hz 120VAC - 60Hz
280 W
280 W
2,5 A
4,5 A
575 W
575 W
2,5 A
4,5 A
8 µF
30 µF
1,6 Rpm
1,9 Rpm
-20 ÷ +50 °C
-20 ÷ +50 °C
IP20
IP20
30 %
30 %
9 Kg
9 Kg
3W
3W
5A
8A