QUICK CONFIGURATION

This paragraph concerns a quick procedure to set the control
unit and set it at work immediately. We recommend following
these instructions, in order to check quickly the correct
operation of control unit, motor and accessories, and then
changing the configuration in case of any non-satisfactory
parameter. Please refer to the paragraph "Control unit
configuration" for the item position inside the menu, as well as
for the available options for each item.
1. Call up a default configuration (item dEF.).
Select AntE for a door, select Scor for other
configurations (sliding, rolling, sectional, etc.).
2. Set items StoP, Foto, CoSt and FC.En according
to the safety devices installed on the door.
3. Start the self-learning cycle (item APPr).
This last operation will close the configuration menu and store
set up parameters.
Self-learning procedure:
• In case the end of stroke or the obstacle sensor has been
enabled, the door will be activated in closing direction until
the stop end or the closing end of stroke is reached.
• In case NEITHER the ends of stroke OR the obstacle sensor
have been enabled, be sure that the door is completely
closed when the procedure is started up.
• The door will be activated in opening direction until the stop
end or the opening end of stroke is reached.
• In case the sensors have not been enabled, or if you realize
that they do not signal the position to the control unit, you
must send a START command when the door reaches its
max. opening position.
• The door will be activated in closing direction until the stop
end or the closing end of stroke is reached.
• In case the sensors have not been enabled, or if you realize
that they do not signal the position to the control unit, you
must send a START command must be sent when the door
reaches its fully closed position.
WARNING: if the function PHOTOCELL SHADOW ZONE is
active and all the working conditions are satisfied (limit
switches enabled and start function during the opening phase
disabled), the intervention of the photocell during the self-
learning does not open the door; the control unit automatically
sets the parameters of the shadow zone in order to disable the
photocell when the door passes in the position of its
intervention.

CONTROL UNIT CONFIGURATION

This paragraph concerns the step-by-step procedure to set all
operation parameters of PD11 control unit. You can either
follow all procedure steps and perform a complete control unit
configuration or select and adjust interesting items only. As for
both cases, you will have to perform the right exit procedure
through item FinE, in order to activate your new configuration.
PD11 control unit provides for a self-learning procedure of
working times; therefore, we recommend that you set up a
standard configuration first (see previous paragraph), then you
carry out the self-learning and finally you change any
unsatisfactory items.
Default value loading
The value of all menu items can be brought to a standard value (see
final recap table) by means of only one command. There are two sets
of values available:
Si
upload default values
no
keeps the previous configuration (if the control unit is new, the
data are the default ones)
After loading default values, the other menu items can be scrolled and
each parameter can be changed; exit from default menu will cause the
automatic selection of the next item.
Opening time
The motor will be operated for the setup time in the opening phase;
in case there is an obstacle or the end of stroke operates, the control
unit can stop the opening phase before the relevant time expires.