tiM TIMER the relay closes when a remote control arrives on channel 4 and opens after the set time
biSt BISTABLE the relay changes each time a remote control arrives on channel 4
Mon MONOSTABLE the relay keeps closed until a signal given by the remote control on channel 4 arrives.
Closing after transit
During the automatic operation, the pause count down starts from the
set up value each time a photocell operates during the pause.
If the photocell operates during the opening time, this time will be
immediately stored as pause time.
This function allows having a fast closing as soon as transit through
the door is completed, therefore, a time shorter than CH.AU is
generally used.
Ch.AU will be used when 'no' is set up.
As for semi-automatic operation, this function is not active.
Pause after transit
In order to let the door open for the shortest possible time, it is
possible to stop the door once the passage before the photocells is
detected. If the automatic working is enabled, the time of the pause is
Ch.tr.
Start input function
This menu allows you to choose the functioning method of the
activation input.
StAn
Standard functioning of the Start input according to the
menu settings.
no
The Start input from a terminal board is not on. The cycle can
only be activated via radio.
29

Courtesy lights

Thanks to the output COURTESY LIGHT
the control unit PD11 allows the
connection of an electric appliance (e.g.
courtesy light or garden lights), controlled
automatically or by means of the special
transmitter key.
The PD11 central unit also has a light
bulb included as a courtesy light.
t.LUC the relay closes when a start or a
pedestrian start control is given
and opens after the set time. It
works in the same way whit a
remote control on channel 4.
CiCL the relay keeps closed during the
whole opening/closing phase. In
case of intervention of a remote
control on channel 4, it keeps
closed for the time set by item
T.LUC
AUS auxiliary output with settable
operation logic
In this last case, the COURTESY LIGHT
output becomes an auxiliary output to
which it is possible to link one of the
following operation logics: