Herunterladen Inhalt Inhalt Diese Seite drucken

V2 Vega-C series Bedienungsanleitung Seite 34

Elektromechanisches stellglied 230v/120v für schwenktüre. digitalsteuerung eingebaut
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 55
Anti-skid
When an opening or closing operation is interrupted by a command or
for the intervention of the photocell, the set-up time for the opposite
movement would be excessive, so the control unit operates the motors
only for the time necessary to recover the actually covered journey.
This could be not sufficient, particularly in the case of very heavy
gates, as because of the inertia at the inversion moment the door
runs an extra space in the previous direction that the control unit is
not able to take into account.
If after an inversion the door does not return exactly to the starting
position, it is possible to set an anti-skid time that is added to the
time calculated by the control unit in order to recover the inertia.
WARNING: If function ASM is disabled, the door goes backward
until it comes to the end stops. In this phase the control unit does not
activate the slow down function before the end stops are reached and
any obstacle that comes across after the inversion is considered as
an end of stroke.
Obstacle Sensor Enabling
This menu allows the sensitivity adjustment of the obstacle sensor
over 10 levels, from 1 to 10. By setting up "0", sensors will be
disabled, increasing the value the sensivity increase.
The control unit automatically adjusts the sensor on the most suitable
level, according to each motor set up power.
In case the safety operation is deemed not to be fast enough, the
sensitivity level can be slightly increased.
If the door stops where no obstacles are present, you should reduce
the sensitivity level.
(See paragraph "Obstacle sensor operation" hereafter).
Counter viewing
This menu allows viewing the counter of completed
opening cycles and it also enables the final user to set
up the times of service required (see paragraph
"Reading of cycle counter" below).
Automatic Learning of the Operation Time
This menu will activate a procedure enabling the control unit to
automatically find the best duration of the operation time.
(See paragraph "Quick Configuration").
When you select Go, configuration menu closes and the learning cycle
starts.
32

Werbung

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Vega120v-c

Inhaltsverzeichnis