INSTALLATION
Installation of control unit and safety devices must be carried
out with power disconnected.

POWER SUPPLY

The control unit must be fed by a 230V 50Hz (120V - 50/60Hz
for the model PD11-120V) electric line, protected by a
differential magnetothermal switch complying with the law
provisions in force.
Connect power supply cables to terminals L and N of PD11
control unit.

COURTESY LIGHTS

Thanks to the output COURTESY LIGHT the control unit PD11
allows the connection of an electric appliance (e.g. courtesy
light or garden lights), controlled automatically or by means of
the special transmitter key.
The output COURTESY LIGHT is a simple N.O. contact with no
power supply.
Connect the cables to terminals B1 and B2.
The PD11 central unit also has a light bulb included as a
courtesy light (230V/120V - 40W max - E14).

WARNING LIGHT

Thanks to the WARNING LIGHT output, the PD11 central unit
allows you to monitor the state of the door in real time and the
kind of flashing signal indicates the four possible conditions:
STOP
light off
IN PAUSE light always on
OPENING the light flashes slowly (2 Hz)
CLOSING the light flashes rapidly (4 Hz)
The output provides the connection of a 24V bulb. The
maximum charge shall be included in the 3W at the disposal
for the accessories. Connect the cables to terminals J7 and J9.

PHOTOCELL

PD11 control unit supplies a 24VAC power supply to photocells
and it can perform a photocell operation test before starting
the door opening phase. Photocell power terminals are
protected by an electronic fuse that stops current in case of
overload.
The photocells are active only during the closing phase and, if
required, with standstill door. In case intervention, the control
unit immediately opens the door, not waiting for the release.
• Connect power supply cables of photocells transmitter
between terminals J7 and J8of the control unit.
• Connect power supply cables of photocells receiver between
terminals J6 and J7 of the control unit.
• Connect receiver output between terminals J4 and J5 of the
control unit. Use outputs having normally closed contact.
WARNING:
• if several couples of photocells are mounted, their outputs
must be connected in series.
• In case of reflection photocells, power supply must be
connected to terminals J7 and J8 of the control unit to
carry out the operation test.

SAFETY RIBBONS

The control unit PD11 is equipped with a specially provided
input to control safety ribbons; the intervention of the edge
reverses the motion for 3 seconds either during the opening
and/or the closing phase. This input can control either the
classic edge with N.C. contact, or the conductive rubber ones
with nominal resistance 8,2 kohm.
Connect the cables of the safety ribbons between terminals J1
and J4 of the control unit.
WARNING:
• When using more ribbons with N.C. contact, the inputs have
to be series connected.
• If using more conductive rubbers, the outputs have to be
cascade connected and only the last one has to be
terminated on the nominal resistance.
23