Electrical installation

Connection to the IT system

Connection to the IT system
For a trouble-free operation on the IT system, observe the following measures:
• Connect an isolating transformer upstream.
• Remove the IT screws. Otherwise the monitoring devices of the IT system will be triggered because
internal components are connected to protective earth (PE).
The use of the safety-related function STO is not permissible in the IT system.
I55AE125x, I55AE137x
I55AE155x, I55AE175x, I55AE222x, I55BE230x, I55BE240x
TX10