Herunterladen Inhalt Inhalt Diese Seite drucken

Terminal Data; Fusing Data - Lenze i550 Montage- Und Einschaltanleitung

0.25 kw ... 132 kw 0.5 hp ... 175 hp
Vorschau ausblenden Andere Handbücher für i550:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Electrical installation
Mains connection
1-phase mains connection 120 V

Terminal data

Inverter
Inverter
Connection
Connection type
Max. cable cross-section
Stripping length
Tightening torque
Required tool

Fusing data

EN 60204-1
Inverter
I55AE125A
I55AE137A
I55AE175A
I55AE211A
154
kW
0.25 ... 0.37
Mains connection X100
Pluggable screw terminal
mm²
2.5
mm
8
Nm
0.5
0.5 x 3.0
Fuse
Characteristic
gG/gL or gRL
gG/gL or gRL
gG/gL or gRL
gG/gL or gRL
I55AExxxA
0.75 ... 1.1
6
8
0.7
0.6 x 3.5
Circuit breaker
Max. rated
Characteristic
current
A
16
B
16
B
25
B
25
B
0.25 ... 1.1
0.25 ... 1.1
PE connection
Motor connection
X105
PE screw
Pluggable screw
terminal
6
10
2
Torx 20
0.5 x 3.0
Earth-leakage circuit
breaker
Max. rated
current
A
16
≥ 30 mA, type A or B
16
≥ 30 mA, type A or B
25
≥ 30 mA, type A or B
25
≥ 30 mA, type A or B
2.5
8
0.5

Quicklinks ausblenden: