First tighten the neck straps (1) evenly,
then the temple straps (2) and finally
the front strap (3).
1)
Fit the helmet
, close the chin strap
and check that the helmet is sitting
firmly on the head. Retighten the chin
strap if necessary.
Manually seal the connector and
breathe in to produce a negative
pressure.
Hold your breath for a moment.
The negative pressure should be maintained. If not, retighten the
straps.
Repeat the last 2 steps twice.
Never use a full face mask that leaks!
If the full face mask leaks, there is a risk of poisoning!
Seal the connector and breathe out forcefully. It must be possible
for the exhaled air to escape without obstruction. If not, see
"Visually inspect the exhalation valve" on page 13.
Connect the positive pressure self-contained breathing apparatus
or positive pressure hose breathing respirator
Check that the demand valve is securely fitted by turning it and
pulling on it forcefully. Have the tightness and correct connection
checked by a second person.

Extreme operating conditions

Low temperatures
If it is not already coated, treat the inside of the visor with "klar-pilot"
anti-misting gel to prevent it from fogging up
visors.
1)
Note the corresponding Instructions for Use.
3
WARNING
1)
.
1)
. Do not wipe coated
High temperatures/Thermal cycling
2
If bubbles appear in the visor, it is a sign that the visor is becoming
soft. In this case, leave the danger zone immediately, as the full face
1
mask can start to leak.
For visors marked PC/CC, the coating of the visor may blister and
come off in places. The function of the full face mask will not be
restricted as a result. It will continue to be usable until the end of the
deployment. Replace the visor after use.
Chemicals
Some substances can be absorbed by the material of the full face
mask or may even diffuse through it. Further information can be
obtained from Dräger.

After use

Release the demand valve
Remove the full face mask:
Insert index finger behind the tabs on
the neck straps and press the buckles
forwards with the thumbs whilst
simultaneously pulling the full face
mask forward off your face and then up
and back over your head.

Maintenance

Always test for leaks after servicing and/or replacing components.

Cleaning and disinfection

Before cleaning, remove any accessories from the full face mask and
1)
clean them separately
WARNING