- Press
and you will see the most recently entered calibration value or the default setting (15 kg).
- Carry out calibration test 2 as described at calibration test 1.
- Enter the calibration value with
Press
to continue. The following text appears on the screen:
NOTE: For accurate metering we recommend to carry out at least TWO calibration tests at position CAL. 1 and
TWO calibration tests at position CAL.2.
- Press
if you want to perform the calibration procedure once more. Press
and to start spreading.
If you press
the calibration procedure starts again and the average over the TWO weights (for positions CAL.1
and CAL.2) will be calculated.
NOTE: If the application rate (in kg/ha), working width or forward speed for the same fertiliser on the same day
changes to such an extent that you pass the 70 kg/min limit, then switch fine metering on or off. Use the
correct calibration values!
Calibration test with fine metering
- Press
to call up the following text:
- Press
and the screen will show:
- Confirm with
, then press
- Press
and you will see the most recently entered calibration value or the default setting (15 kg).
- Start the tractor and switch on the pto at the correct rpm for your spreader and working width. Refer to the
manual and the spreading table.
- Then press
. The selected metering plate will be opened. The display shows the remaining time in seconds.
The metering plate will automatically close at the end of the test.
If you press
during the calibration test, the metering plate will directly close. The previous metering value will
be maintained.
- Switch off the pto after completion of the calibration test and determine the weight of the collected fertiliser.
Allow for the weight of the receptacle.
40
WEIGHT 2=
,
and confirm with
CAL. AGAIN ?
:
Fine metering =
Fine metering =
and the selected calibration procedure will be displayed:
CAL. 1 TIME =
WEIGHT 1=
xx.x kg
.
to leave the calibration menu
no
yes
60 s
xx.x kg