5
IO-Link interface (continued)
For the analog and object output values, the different
modes can be selected via the following settings:
Value
Mode
0
Disable
1
Left object
2
Left slit
3
Right object
4
Right slit
5
Diameter
*: Modes 9 and 10 are not available for the analog output values.
5.3.4

Diagnostic data

The data described in the diagnostics area can be retrie-
ved under the following indices:
Index
Name
0x57
Time function
- Operating hours counter
- Time since last maintenance in h
- Operating hours since switching on
- Number of starts
0xB7
Sequential counter
- Limit reached
(Bit 1 Counter 1 / Bit 2 Counter 2)
- Status counter 1
- Status counter 2
0xE0
Optical properties
- Ambient light minimum
- Ambient light maximum
- Laser light minimum
- Laser light maximum
- Sampling period in 0.1ms
16
english
Value
Mode
6
Slit
7
Object position
8
Slit position
9
Objects counting*
10
Slits counting*
Subindex
Size
1
UINT32
2
UINT32
3
UINT32
4
UINT32
1
UINT8
2
UINT16
2
UINT16
1
UINT16
2
UINT16
3
UINT16
4
UINT16
5
UINT16
Access
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R