BTL6-U110-M _ _ _ _ -PF-S4
Micropulse Transducer in a Flat Profile Housing
6
IO-Link interface (continued)
Null point offset
Like the process data value, this parameter is a signed
32-bit decimal value. The programmed value must be
within the null and end point in the valid measuring range.
The value is deducted from the actual output value as a
simple offset and therefore shifts the position of the
magnet to an arbitrary point in the measuring range where
the value 0 is output. Access takes place via subindex 0.
Takeover of null point offset
The current measured value can be applied in the null point
offset using this Boolean parameter. After setting the
parameter to "True," the value 0 is output at the current
position of the magnet. Setting "False" has no effect.
Access takes place via subindex 0 with the values 0xFF for
"True" and 0x00 for "False."
6.5

Diagnostic data

The BTL6-U110-... reports the following diagnostic data to
the controlling system:
Event code
Characteristic
0x8C10
Warning
0x8C20
Error
0x8C30
Warning
Tab. 6-6:
BTL6-U110-... diagnostic data
All messages are output both as "incoming" as
well as "outgoing".
www.balluff.com
Error messages
Certain error messages are stored for failed
parameterization:
Error
code
0x8011
0x8012
0x8020
0x8030
0x8033
0x8034
0x8036
Tab. 6-5:
Meaning
"Process variable range overrun - Process Data uncertain"
The magnet is located below the specified measuring range or below the null
point. A process value is output but the data can exceed the linearity limits
specified in the data sheet.
"Measurement range over-run - Check application"
The magnet is located outside of the measurable range and cannot be
detected. No valid data is output. The transferred process data value is the
maximum value of 0x7FFFFFFF or 2147483647.
"Process variable range underrun - Process Data uncertain"
The magnet is located above the specified measuring range or over the end
point. A process data value is output, but the data can exceed the linearity
limits specified in the data sheet.
Error message
"Index not available"
"Subindex not available"
"Service temporarily not available"
"Value out of Range"
"Parameter Length overrun"
"Parameter Length underrun"
"Function temporarily unavailable"
IO-Link specification error messages
english
15