BTL6-U101-M_ _ _ _ -A/B/Y/Z-S4
Transducer – Rod Style
6
IO-Link interface (continued)
6.7

Diagnostic data

The transducer reports diagnostic data to the controlling
system (see Tab. 6-12).
Event code
Characteristic
0×8C10
Warning
0×8C20
Error
0×8C30
Warning
0x8CA0
Warning
Tab. 6-12: Diagnostic data
www.balluff.com
Meaning
Process variable range overrun - Process Data uncertain
The magnet is located below the specified measuring range or below the null
point. A process value is output but the data can exceed the linearity limits
specified in the data sheet.
Measurement range overrun - Check application
The magnet is located outside of the measurable range and cannot be
detected. No valid data is output. The transferred process data value is
0×7FFFFFFC or 2147483644.
Process variable range underrun - Process Data uncertain
The magnet is located above the specified measuring range or above the end
point. A process data value is output. The data can exceed the linearity limits
specified in the data sheet.
Magnet Number Change - temporary error state
The number of magnets was changed in FMM mode. For the duration of the
set diagnostic time, an error is output and the process data is marked as
invalid.
english
19