4

Parameterization and functions

4.1
Introduction
After the unit is powered up, it is ready for operation and
outputs the current measured values. The data are output
according to the parameters set during the last use, or
during initial commissioning or reset to factory settings
according to the standard settings.
Parameters can be changed via the IO-Link interface (see
Chapter 5).
The LEDs on the device serve as status indicators:
LED1 (green): Device is switched on
LED1 (green flashing): IO-Link communication active
LED2 (yellow): Object is in measuring field
4.2

Configuration of the analog output values

Both analog output values [Analog Value 1/2] can be
configured independently of each other. The setting
options are the same for both output values.
The factory setting of the device for analog output value 1
is "left object" and for analog output value 2 "right object".
"Right" and "Left" correspond to the marking on the
receiver housing.
www.balluff.com
The following modes are available:
Mode
Abbr.
Description
Left Obj. LO
For web edge guide control. Object
enters the light band from the left (L).
The distance of the leading / front
edge of the object from the left (L)
edge of the measuring field is
displayed. (This is the first falling
signal edge when evaluating the light
band from R to L.)
Left Slit
LS
First edge of a slit measured from the
left (L) edge of the light band. (This is
the first rising signal edge when
evaluating the light band from R to L.)
Right
RO
For web edge guide control. Object
Obj.
enters the light band from the right
(R). The distance of the leading / front
edge of the object from the right (R)
edge of the measuring field is
displayed. (This is the first falling
signal edge when evaluating the light
band from L to R.)
Right Slit RS
First edge of a slit measured from the
right (R) edge of the light band. (This
is the first rising signal edge when
evaluating the light band from L to R.)
Diame-
D
Object diameter (outside diameter,
ter
i.e. holes or slits within the object are
ignored)
Slit
S
Slit width (inside diameter)
Pos.
PO
Object position (center point)
Obj.
measured from the left side
Pos. Slit
PS
Slit position (center point) measured
from the left side
Off
Function is deactivated. The output
value is always 0.