Diagnostic Data - Balluff BLA D-Serie Betriebsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

BLA Series D
Balluff Light Array
6
IO-Link interface (continued)
For the analog and object output values, the different
modes can be selected via the following settings:
Value
Mode
0
Disable
1
Left object
2
Left slit
3
Right object
4
Right slit
5
Diameter
Tab. 6-7:
Object output modes
*: Modes 9, 10 and 11 are not available for the analog
output values.
www.balluff.com
Value
Mode
6
Slit
7
Object position
8
Slit position
9
Objects counting*
10
Slits counting*
11
Any object*
6.3.4

Diagnostic data

The data described in the diagnostic area may be accessed
through following indices:
Index
Name
0x52
Temperature
- Up-to-date
- Min. since power-on
- Max. since power-on
- Min. since first start-up
- Max. since first start-up
0x53
Temperature alarm value
- Lower limit
- Upper limit
0x54
Laser
- Status
- ID
- Serial number
- Operating time [s]
- Number of switch-on
procedures
- Operating current
- Temperature
- Error
0x57
Operating time
- since power-on [s]
- total [s]
- since maintenance [s]
0x58
Switch-on procedures
- total
- since maintenance
0xE0
Optical properties
- Ambient light minimum
- Ambient light maximum
- Laser light minimum
- Laser light maximum
- Sampling period in 0.1 ms
Tab. 6-8:
Diagnostic data
Sub-
Size
Access
index
1
UINT16
R
2
UINT16
R
3
UINT16
R
4
UINT16
R
5
UINT16
R
1
UINT8
R
2
UINT16
R
1
UINT32
R
2
UINT32
R
3
UINT32
R
4
UINT32
R
5
UINT32
R
6
UINT32
R
7
UINT32
R
8
UINT32
R
1
UINT32
R
2
UINT32
R
3
UINT32
R
1
UINT32
R
2
UINT32
R
1
UINT16
R
2
UINT16
R
3
UINT16
R
4
UINT16
R
5
UINT16
R