Technical data

6.1
Dimensions
6.2

Mechanical data

Material housing
Aluminium anodized
Material
Emitter: Antireflective coated glass
active surface
Receiver: Interference filter (glass)
Protection class
IP 67
according to
IEC 60529
Weight
- BLA emitter
100 g
- BLA receiver
120 g
Dimensions
- housing
68mm x 38mm x 20mm
(equal for transmitter and receiver)
- Length pigtail
250mm
6.3

Electrical data (typical)

Operating voltage Ub
18...30 V DC
Residual ripple
<10%, max 2 V
No-load current
<100 mA
LED Indicators
LED1 green: Operation indicator
LED2 yellow: Object indicator
Sampling period
1.0 ms...100 ms
Parameterization
Via IO-Link
Connection
Cable 4-pin: M8 plug to M8
emitter-receiver
socket
www.balluff.com
6.4

Optical data (typical)

Light type
Laser class
Ambient light
Light band width (active area) 16.25 mm
Max. emitter-receiver
distance
Resolution
Smallest object
Maximum deviation of the
measured value over the
entire distance range bet-
ween object and receiver [at
object-receiver distance]
Repeat accuracy [at object-
receiver distance]
The decrease in accuracy with larger transmit-
ter- receiver distances is mainly due to diffrac-
tion effects on the object. In order to keep these
effects as low as possible, it is always advanta-
geous to place the object to be detected as
close as possible to the receiver.
Laser, red light 650 nm
max. 5000 Lux
2000 mm
10 µm
0.4 mm
[<250 mm]
0.7 mm
[<1000 mm]
1 mm
[<2000 mm]
For rod (d=8 mm)
± 20 µm
[<250 mm]
± 50 µm
[<1000 mm]
± 100 µm
[≤2000 mm]
For wire (d=1 mm)
± 40 µm
[<250 mm]
± 150 µm
[<1000 mm]
± 200 µm
[≤2000 mm]
± 10 µm
[<250 mm ]
± 20 µm
[<1000 mm]
± 70 µm
[≤2000 mm]