IO-Link interface

5.1
IO-Link data
Due to its compact design, the BLA16 can only be para-
meterised and read out via IO-Link.
The characteristic parameters of the interface are:
Data transfer rate
Minimum cycle time
Process data length
IO-Link Revision
Frame type
5.2

Process data

For continuous data transmission, 14 bytes of process
data (PDI) are transmitted:
No.
Length
Type
variable
(bit)
1
32
IntergerT
2
32
IntergerT
3
8
UIntergerT
4
16
UIntergerT
5
16
UIntergerT
6
8
Bitmask
The analog output values are in µm, the value range here
is from 0 to 16256, which corresponds to the active
measuring range of the sensor.
The object output value gives the number of the detected
object. (0: no object; 1-6: detected objects; 7: unknown
object).
If the mode objects counting or slits counting is selected,
the number of detected objects, up to a maximum of 16,
is output in the object output value.
If activated, the counter status of the corresponding
sequential counter is output in the corresponding counter
output value.
If analog output, object detection or counter are deactiva-
ted, the corresponding output values are set to 0.
Several status messages are output simultaneously in
variable no. 6:
Bit 3 or bit 4 indicates whether the counter 1 or counter 2
has reached the set limit.
Bit 6 indicates whether autoblanking was activated during
the last teach event.
If no light arrives at the receiver, bit 7 is set to 1. With this,
a completely blocked light band can be detected.
14
english
COM2 (38,4 kBaud)
6.8 ms
14 Byte PDI + 1Byte PDO
1.1
1.0
2.V
1.2 / 1.1
Content
Analog output value 2
Analog output value 1
Object output value
Counting output value 1
Counting output value 2
Bit 3
Counter limit 1
reached
[Counter 1 Flag]
Bit 4
Counter limit 2
reached
[Counter 2 Flag]
Bit 6
Autoblanking
active
Bit 7
Data invalid
The device cannot distinguish whether the light
band is completely blocked or whether the laser
has failed or is not plugged in.
In addition to the PDI, there is a PDO value:
No.
Length
Type
variable
(bit)
1
8
Bitmask
This value can be used to reset the sequential counter to
0. This happens when the value is changed from 0 to 1.
5.3

Parameter data

5.3.1

Identification data

Object
Length
Index
name
(Byte)
0x07
Vendor ID
2
0x09
Device ID
3
Vendor-
0x10
7
Name
Vendor-
0x11
15
Text
Product
0x12
14
designation
0x13
Product ID
7
0x14
Product Text
19
0x15
Serial No.
8
Hardware
0x16
4
Revision
Firmware
0x17
5
Revision
Application
0x18
32
tag*
R
O:
read-only
R/W:
read and write access
*:
The application tag can be defined by the user.
5.3.2

System Commands

Under the index 0x02 (length 1 byte), the system com-
mands for executing the corresponding functions are
available under the values listed below:
Value
Function
0x80
Restart device
0x82
Restore factory settings
0xA0
Signal normalization
0xA5
Reset maintenance interval
0xA6
Set sequential counter to 0
Content
Bit 0
Reset counter
Access
Default value
RO
888 (0x0378)
721409
RO
(0x0B0201)
RO
"BALLUFF"
RO
"www.balluff.com"
"BLA 016C-002-
RO
00,25-S75"
RO
"BLA0007"
RO
"Balluff Light Array"
RO
(individuelle S/N)
RO
Vx.x
RO
Vx.xx
R/W