4.6 Chimney and flue pipe
• The fireplace can be connected to a chimney and flue pipe
approved for solid fuel fireplaces with flue gas temperatures
as specified in "2.0 Technical Data".
• The cross-section of the chimney must be at least that of the
flue pipe. Use "2.0 Technical Data" to calculate the correct
chimney cross-section.
• The fireplace must be connected to a chimney and flue pipe
approved for solid fuel fireplaces with flue gas temperatures
as specified in «2.0 Technical Data».
• Before a hole is made in the chimney, the fireplace should be
test-mounted in order to correctly mark the position of the
fireplace and the hole in the chimney. See Fig. 1 for minimum
dimensions. NB: This does not apply if the stove is installed
inside a hearth.
• NB: A sweeping hatch is not required if the angle of the flue
pipe bend is 45° or less. If the angle is greater than 45°, a flue
pipe bend with a hatch must be installed to allow sweeping.
Please note that it is extremely important for connections to
have a degree of flexibility. This is to prevent any movement in
the installation leading to the formation of cracks.
NB: A correct and airtight connection is extremely important for
the function of the product.
Weight must not be transferred from the fireplace structure to the
chimney. The fireplace structure must not hinder the chimney's
ability to move, and must not be anchored to the chimney.
For recommended chimney draught, see "2.0 Technical Data". If
the draught is too strong, a flue pipe damper can be installed
and used to reduce the draught.