Table of contents
Installation manual with technical data
1.0
Regulatory information .................................2
2.0
Technical data ................................................2
3.0
Safety ..............................................................3
4.0
Installation ....................................................3
5.0
Daily use ...................................................... 26
6.0
Maintenance ............................................... 28
7.0
Servicing ...................................................... 29
8.0
Optional Extras ............................................ 31
9.0
Recycling ....................................................... 31
10.0 Warranty ....................................................... 31
On all our products there is a label
Product:
Jøtul
indicating the serial number and
Room heater fired by solid fuel
year. Write this number in the
Standard
:
Minimum distance to adjacent combustible materials:
place indicated in the installation
Minimum distance to adjacent combustible materials:
Emission of CO in combustion products
:
Flue gas temperature
:
instructions.
Nominal heat output
:
Efficiency
:
Operation range
:
Fuel type
:
Operational type
:
The appliance can be used in a shared flue.
Always quote this serial number when
Country
Classification
Certificate/
Approved by
contacting your retailer or Jøtul.
standard
Norway
Klasse II
SP Sveriges Provnings- och
Sweden
SP
OGC
Forskningsinstitut AB
SP Swedish National
Testing and Research
EN
EUR
Intermittent
Institute
Follow user`s instructions. Use only recommended fuels.
Montage- und Bedienungsanleitung beachten.
Verwenden Sie nur empfohlenen Brennstoffen.
Respectez les consignes d'utilisation. Utilisez uniquement
les combustibles recommandés.
Serial no: Y-xxxx, Year: 200x
Manufacturer:
221546
Jøtul AS
POB 1441
N-1602 Fredrikstad
Norway
2
Serial no.

1.0 Regulatory information

The installation of a fireplace must take place in accordance with
each country's laws and regulations.
All local ordinances, including those that refer to national and
European standards, must be complied with when products are
installed.
The installation can only be taken into use after it has been
checked by a qualified inspector.
A rating plate made of a heat-resistant material is fixed to the
heat shield. This provides information on identification and
documentation of the product.
2.0 Technical data
Material:
Finish:
Type of fuel:
Max. log length:
Smoke outlet:
Flue pipe dimension:
Weight:
Optional extras:
Product dimensions, distances: See fig. 1
Technical data in accordance with EN 13229
Nominal heat output:
Efficiency:
CO emissions (13% O2):
CO emissions (13% O2):
OGC emissions (13% O2):
Dust emissions (13% O2):
Flue gas temperature:
Flue gas flow rate:
Chimney draught, EN 13229:
Recommended draught
with smoke outlet:
Fuel consumption:
Kindling quantity:
Max. kindling:
Operation:
"Intermittent combustion" here means normal use of a
stove. That is to say, if you want to continue producing
heat, you add more fuel as soon as the previous load of
wood has burnt down to embers.
Cast iron
Black Paint
Wood
50 cm
Top or rear-installed smoke
outlet (rotated 45°).
Ø 150 mm
Approx. 110 kg
Leg Rack complete, door lock
complete - left, frames, sheet
metal grids, and convection
top plate.
7 kW
77%
0.07%
884 mg/Nm3
60 mg/Nm3
14 mg/Nm3
305°C
7,1 g/s
12 Pa
16-18 Pa
2.3 kg/h
1,7 kg
3,4 kg each time and 3,8 kg/h
Intermittent

Werbung