Herunterladen Inhalt Inhalt Diese Seite drucken

Technical Data/Trouble Shooting El - HANSGROHE PHARO Duschtempel 100 Montageanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

T e c h n i c a l D a t a /
t r o u b l e s h o o t i n g E L 4 0
Halogen G4
12 V/10W
Technical Data
Power supply:
Rated output:
Transformer:
Protection type:
Minimum water pressure:
Recommended pressure:
Test pressure:
Hot water temperature:
Recommended hot water
temperature:
Safety stop:
Flow rate at 3 bar pressure
Over head shower:
Hand shower:
Body showers:
Hand showers + body showers:
Over head showers+ body showers
Over head showers + hand showers
54
(EL = electronic version)
Removing halogen spotlight
Turn cover counter clockwise and remove it.
The halogen bulbs (12 Volt/10 Watt) are available from an
electrician. Do not touch the halogen bulbs with your hand.
Steam bath
Shower Temple 100 EL 40 cannot used in connection with a
steam bath! No humidity on the electronic components is
allowed.
Combination boiler
The Shower Temple 100 EL 40 with 1/2" thermostat cannot
230V~ 50/60Hz
be used with a combination boiler.
35 VA
Protection Class II
Hot water supply
IP 65
The hot water supply must be at least 2° C higher than the
1.5 bar
desired mixed water temperature. The temperature difference
2 - 5 bar
on the supply connection should be 50° C.
10 bar
max. 70° C
Pressure fluctuations
Any fluctuations between the cold and hot water supply must
60° C
be balanced.
42°C
22 l/min
13 l/min
18 l/min
26 l/min
28.5 l/min
31.5 l/min

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis