F i t t i n g a n d s e a l i n g t h e s i d e g l a s s p a n e l s
1
4
5
7
44
2
3
6
8
Fitting the side glass panels
The side glass panels are identical, the sealing strip (3) is cut
off about the length of the groove in the column.
Slide the side glass panel coming from the inner side into the
column, the Pharo-Logo should be legible from the outer side.
Turn the side glass panel until it stops at the clamping ledge.
The sealing profile should be cut off at the clamping ledge,
mark the sealing profile respectively (4).
Remove side glass panel and cut off the sealing profile.
Before insert the side glass panel seal the groove in the area
next to the shower tray (1). Secure the side glass panel with the
clamping ledge by using hexagonal head screw M6x10 (6).
Put on the cover caps (5).
Inserting the sealing profile
Lightly grease the sealing profile (7) with enclosed silicon
grease. Press sealing profile from the inner side between side
glass panel and the column.
Sealing of the side glass panels
Seal both clamping ledges, side glass panels and both columns
in the area next to the door (8). Use a suitable bathroom filler.