Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The arm of the shower head is intended only to hold
the shower head. Do not load it down with other
objects!
Children as well as adults with physical, mental and/
or sensoric impairments must not use this product
without proper supervision. Persons under the influ-
ence of alcohol or drugs are prohibited from using
this product.
Do not allow the streams of the shower touch sensi-
tive body parts (such as your eyes). An adequate
distance must be kept between the shower and you.
The product may not be used as a holding handle. A
separate handle must be installed.
The shower system may only be used for bathing,
hygienic and body cleaning purposes.
The hot and cold supplies must be of equal pres-
sures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be oberserved.
• The installation dimensions stated in these installation
instructions are ideal for people of approximately
1700 mm in body height. The dimensions can be al-
tered if required. In this case, pay attention to the fact
that a change of installation height will also change
the minimum height, and that the altered mounting
dimensions must be taken into consideration.
• Where the contractor mounts the product, he should
ensure that the entire area of the wall to which the
mounting plate is to be fitted, is flat (no projecting
joints or tiles sticking out), that the structure of the wall
is suitable for the installation of the product and has
no weak points. The enclosed screws and dowels are
only suitable for concrete. For another wall construc-
tions the manufacturer's indications of the dowel
manufacturer have to be taken into account.
4
English
• The mesh washer must be insert to protect the over-
head shower against incoming dirt by pipework. In-
coming dirt leads to defects or/and can damage parts
of the shower; such caused faults voids all liability and
guarantee claims.
• The product is not designed to be used with steam
baths!
• If required, the bottom part of the pipe between the
fixture and the shower head can be shortened with a
fine-toothed saw.
• If the continuous water heater causes any problems,
or you have different water pressures you must
install a water limiter to the cold supply, (ordered
separately,article number 97510000).

Technical Data

Operating pressure:
Recommended operating pressure:
Test pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Centre distance:
Connections G 1/2:
Thermal disinfection:
Safety against backflow
The product is exclusively designed for drinking water!
max. 1 MPa
0,15 - 0,5 MPa
1,6 MPa
max. 80°C
65°C
150 ± 12 mm
cold right - hot left
max. 70°C / 4 min