Herunterladen Inhalt Inhalt Diese Seite drucken

HANSGROHE PHARO Duschtempel 100 Montageanleitung Seite 55

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

T e c h n i c a l D a t a /
t r o u b l e s h o o t i n g E L 4 0
Failure
No function
Light fails
One halogen
spotlight fails
No water flow
when using
the shower
After a certain time
of showering the
temperature changes
Outlet temperature does
not correspond with the
adjusted temperature
Possible cause
No current available
Transformer defect
Connection to the lighting
is interupted
Halogen spotlight defect
Floor shut-off device is closed
Shut-off valve (Thermostat)
is closed
Filters are polluted
Not enough stored
hot water
Temperature of the feed
hot water is too low
No motor alignment was
performed
(EL = electronic version)
Remedy
Check current conductor
Replace transformer
Contact manufacturer service
Plug in the connector of the lights
Replace halogen bulb (12 V/10 Watt)
Open floor shut-off device
Open shut-off valve
Clean filter
(Servicing thermostat)
Increase hot water storage or
temperature of the water stored
Increase the temperature of the
hot water cylinder
Perform motor alignment
55

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis