Safety Notes

Gloves should be worn during installation to prevent crushing and
cutting injuries.
The arm of the shower head is intended only to hold the shower head.
Do not load it down with other objects!
Children as well as adults with physical, mental and/or sensoric im-
pairments must not use this shower system without proper supervision.
Persons under the influence of alcohol or drugs are prohibited from
using this shower system.
Do not allow the streams of the shower touch sensitive body parts (such
as your eyes). An adequate distance must be kept between the shower
and you.
The shower system may only be used for bathing, hygienic and body
cleansing purposes.
The hot and cold supplies must be of equal pressures.

Installation Instructions

• The pipes and the fixture must be installed, flushed and tested as per the
applicable standards.
• Prior to installation, inspect the product for transport damages. After it
has been installed, no transport or surface damage will be honoured.
• During installation of the product by qualified trained personnel, make
sure that the entire fastening surface is even and smooth (no protruding
seams or tile offset), that the finish of the wall is suitable to apply the
product and has no weak points.
• The mesh washers must be installed to protect against incoming dirt by
pipework. Incoming dirt can impair the function and/or lead to damages
on functional parts of the fixture; Hansgrohe will not be held liable for
resulting damages.
• This mixer cannot be used in conjunction with hydraulically, electronically
or thermally controlled instantaneous heaters.

Technical Data

Operating pressure:
Recommended operating pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
4
English

Symbol description

max. 0,6 MPa
0,2 – 0,4 MPa
max. 60°C
42°C
max. 70°C / 4 min
Assembly see page 21
Do not use silicone containing acetic acid!
Dimensions (see page 6)
Flow diagram (see page - 20)
Installation example (see page - 20)
Center shower tub
X
Warm water
Cold water
The wall must be reinforced in this area.
Shut off valve
Quattro 4-Way Diverter Valve
Quattro
Trio 2-Way Diverter Valve with integrated Shut-off
valve
Trio
Plug the unused outlet.
The waste drain performance must be more than
50 l/min.
> 50 l/min
Waste
Raindrain
Cleaning (see page 24)
Safety gloves must be worn
Eye protection must be worn
Decalcifier (Citric acid base)
Avoid contact with eyes and skin. If this product
contacts your eyes, rinse thorougly with water.
natural sponge
Spare parts (see page 27)
Test certificate (see page
)