8.2.4 Setting to min. curve duty
Description of function, see section 7.5 Max. or min.
curve duty.
To change over to the min. curve, press
continuously until "MIN" illuminates, see fig. 24. To
change back, press
continuously until the desired
setpoint is indicated.
Fig. 24 Min. curve

8.2.5 Start/stop of pump

To stop the pump, press
"STOP" illuminates. When the pump is stopped, the
green indicator light will be flashing.
To start the pump, press
If the pump is to be stopped, it is
recommended to use the start/stop
input, the R100 or to switch off the
Note
electricity supply. In this way, the
setpoint will remain unchanged when
the pump is started again.
8.2.6 Resetting of fault indications
The fault indications are reset by briefly pressing
any button. The settings remain unchanged. If the
fault has not disappeared, the fault indication will
reappear. The time until the fault reappears may vary
from 0 to 255 seconds.
22
continuously until
continuously.

8.3 R100 remote control

The pump is designed for wireless communication
with the Grundfos R100 remote control. The R100
communicates with the pump via infra-red light.
During communication, the R100 must be pointed at
the pump control panel. When the R100 is
communicating with the pump, the red indicator light
will flash rapidly.
The R100 offers additional possibilities of setting and
status displays for the pump.