6.11.8.2 Revolutions numerator / Revolutions denominator

Together, these two parameters define the Number of revolutions before the
measuring system restarts at zero.
As decimal numbers are not always finite (as is e.g. 3.4), but they may have an infinite
number of digits after the decimal point (e.g. 3.43535355358774...) the number of
revolutions is entered as a fraction.
Numerator lower limit
Numerator upper limit CEH
Numerator upper limit COH
Default numerator
Denominator lower limit
Denominator upper limit CEH
Denominator upper limit COH
Default denominator
Formula for gearbox calculation:
Total measuring range = Steps per revolution *
If it is not possible to enter parameter data in the permitted ranges of numerator and
denominator, the attempt must be made to reduce these accordingly. If this is not
possible, it may only be possible to represent the decimal number affected
approximately. The resulting minor inaccuracy accumulates for real round axis
applications (infinite applications with motion in one direction).
A solution is e.g. to perform adjustment after each revolution or to adapt the
mechanics or gearbox accordingly.
The parameter "Steps per revolution" may also be decimal number, however the
"Total measuring range" may not. The result of the above formula must be rounded
up or down. The resulting error is distributed over the total number of revolutions
programmed and is therefore negligible.
Preferably for linear axes (forward and backward motions):
The parameter "Revolutions denominator" can be programmed as a fixed value of
"1". The parameter "Revolutions numerator" is programmed slightly higher than the
required number of revolutions. This ensures that the measuring system does not
generate a jump in the actual value (zero transition) if the distance travelled is
exceeded. To simplify matters the complete revolution range of the measuring system
can also be programmed.
Printed in the Federal Republic of Germany
11/07/2018
1
256 000
262 144
4096
1
16 384
65 535
1
TR - ECE - BA - DGB - 0076 - 08
Number of Revolutions numerator
Number of Revolutions denominator
 TR-Electronic GmbH 2010, All Rights Reserved
Page 95 of 111

Werbung

Kapitel

Inhaltsverzeichnis
loading

Diese Anleitung auch für:

Ceh-110Ceh-80Coh-110Coh-80C h-110 serie

Inhaltsverzeichnis