6.1.2 COH, TR0DAAAB.GS_

Configuration Operating parameters
PNO Class 1-16
- Count direction
Page 80
PNO Class 1-32
- Count direction
Page 80
- Count direction
- Class 2 on/off
- Commissioning diagnostics
PNO Class 2-16
Page 81
- Scaling function
- Steps per revolution
- Total measuring range
- Count direction
- Class 2 on/off
- Commissioning diagnostics
PNO Class 2-32
Page 82
- Scaling function
- Steps per revolution
- Total measuring range
- Count direction
- Commissioning diagnostics
- Status-byte
TR-Mode,
- Short Diagnostics
High Resolution
- Total measuring range
Page 86
- Revolutions numerator
- Revolutions denominator
- Lower limit switch
- Upper limit switch
- Count direction
- Commissioning diagnostics
- Status-byte
TR-Mode,
- Short Diagnostics
High Resolution
- Total measuring range
+ Velocity
- Revolutions numerator
- Revolutions denominator
Page 87
- Lower limit switch
- Upper limit switch
- Velocity
*
from the bus master perspective
Printed in the Federal Republic of Germany
11/07/2018
Length Features
-
16 bit IN
-
32 bit IN
-
16 bit IN
-
16 bit OUT
-
-
32 bit IN
-
32 bit OUT
-
32 bit IN
32 bit OUT
-
-
-
-
32 bit IN
16 bit IN
-
32 bit OUT
-
-
-
TR - ECE - BA - DGB - 0076 - 08
No measuring system scaling, the measuring
system has the base resolution according to the
nameplate
16 byte diagnosis data
Count direction
Max. steps per revolution ≤ 8192, if higher
resolutions are required, one of the TR-Modes
must be used
Measuring system scaling is possible, however
the number of steps / revolution must be an
integer and the number of revolutions an
exponent of 2
Preset adjustment via the bus
Count direction
Measuring system scaling possible, the number
of steps per revolution can be a decimal number
and the number of revolutions any number (not
an exponent of 2).
Preset adjustment via the bus
Count direction
Soft limit switch function
Measuring system scaling possible, the number
of steps per revolution can be a decimal number
and the number of revolutions any number (not
an exponent of 2).
Preset adjustment via the bus
Count direction
Soft limit switch function
Velocity output
 TR-Electronic GmbH 2010, All Rights Reserved