Installation / Preparation for commissioning

4.2 Type with cable glands

4.2.1 Connection

The connection hood must first be removed from the measuring system to undertake
connection.
The four screws
Figure 1: Removing of the connection hood
PROFIBUS_IN
Pin 1
Pin 2
Pin 3
Pin 4
PROFIBUS_OUT
Pin 1
Pin 2
Pin 3
Pin 4
The terminals for the supply voltage (pin 3 / pin 4) are connected together internally
and can be used as feeding, as well as supply voltage for the subsequent slave.
 TR-Electronic GmbH 2010, All Rights Reserved
Page 68 of 111
(A)
are unscrewed and the hood removed.
PROFIBUS Data A
PROFIBUS Data B
Supply voltage, 11-27 VDC
0 V, GND
PROFIBUS Data A
PROFIBUS Data B
Supply voltage, 11-27 VDC
0 V, GND
TR - ECE - BA - DGB - 0076 - 08
1
IN
Printed in the Federal Republic of Germany
1
OUT
11/07/2018