Before commissioning, always check the BENNING PV 3 and the measuring leads for
damages.
8.1.1

Charging the rechargeable batteries

Before the first use and before each use, fully charge the rechargeable 3.7 V 18650 lithium-ion batteries.
Use the included automatic charger (New i4, NITECORE
-
Use the charger only to charge the rechargeable 3.7 V 18650 lithium-ion batteries (2600 mAh, pro-
tected version) included in the delivery.
-
Connect the charger to a protected shock-proof socket (230 V, 50 Hz) using the included mains con-
nection cable and insert the three rechargeable batteries into the battery holders observing correct
polarity.
-
Charging starts automatically when the batteries are inserted.
-
Depending on the battery type and capacity, the charging current/voltage is automatically set for each
battery holder. For lithium-ion batteries, the charging voltage is preset to 4.2 V.
-
The state of charge of the batteries is indicated by three green LEDs for each battery holder. Charging
is complete when the three LEDs (100 %) of each battery holder light permanently.
Note on manually setting the charging current/voltage:
After inserting the batteries, briefly press button C to select the battery holder used.
-
As long as the green LED of the selected battery holder lights, the charging current can be
increased to 1.5 A (red LED lights up) by pressing and holding button C. If several battery holders
are selected for a charging current of 1.5 A, charging with increased current takes place subse-
quently from left to right.
-
As long as the green LED of the selected battery holder lights, a charging voltage of 3.7 V, 4.2 V
and 4.35 V (green LED) can be set by pressing and holding button V.
c
Please note that the charging voltage for the included rechargeable batteries must be
set to 4.2 V!
8.1.2

Switching the BENNING PV 3 ON/ OFF

-
Press and hold the keys
Acoustic signals confirm that the device is switched on. Press the keys again for approx. 2 seconds to
switch the device off.
-
After approx. 1 minute, the BENNING PV 3 switches off automatically (APO, Auto Power-Off). It
switches on again when the keys
device has switched off automatically.
8.1.3
Setting the automatic switch-off time (APO, Auto-Power-Off)
-
Switch the BENNING PV 3 off by simultaneously pressing the keys
-
Press and hold the
pressed.
-
The LC display 1 shows "OFF" in the first line and the switch-off time (in minutes) in the second line.
-
Each time pressing the
of 10 minutes.
-
Release the
key 6 to store the setting.
8.1.4

Setting the date and the time

The BENNING PV 3 is equipped with an integrated real-time clock which automatically adds a date / time
stamp to each storage process or storage location (see chapter 8.3 "Measured value memory").
To set the date and the time, carry out the following steps:
-
Switch the BENNING PV 3 off by simultaneously pressing the keys
-
Press and hold the
-
The date / time format is displayed as follows:
MM.DD = month (1-12).day (1-31)
YYYY = year
HH.mm = hours (0-23).minutes (0-59)
SS = seconds (0-59)
01/ 2019
2 and
3 for approx. 2 seconds to switch the BENNING PV 3 on.
2 and
key 6 and simultaneously press the keys
key 2 increases the switch-off time by one minute up to a maximum time
key 4 and simultaneously press the keys
BENNING PV 3
) to do this.
®
3 are pressed. An acoustic signal indicates that the
2 and
2 and
2 and
3 .
3 . Keep the
2 and
3 .
3 .
key 6