To activate / deactivate the radio transmission, press and hold the
simultaneously press the
sion has been activated.
-
If the BENNING PV 3 is within the radio range of the BENNING SUN 2, the measured insolation value
(W/m²) is shown on the LC display 1 of the BENNING PV 3.
-
Besides the electric variables (Vo/c, Is/c), an AUTO measurement by means of the BENNING PV 3
additionally measures the insolation, the module and ambient temperature as well as the date / time
stamp of the BENNING SUN 2.
-
If the BENNING PV 3 is outside the radio range of the BENNING SUN 2, the "W/m²" symbol on the LC
display starts flashing. Moreover, "_ _ _ _" is shown on the LC display 1 , if the measured insolation
value is outside the measuring range.
Note:
If the BENNING PV 3 does not receive any radio signal from the BENNING SUN 2, the display indications
are stored with the date / time stamp of the BENNING PV 3.

9. Maintenance

9.1 Error codes

Error code

9.2 Securing the instrument

Under certain circumstances safe operation of the BENNING PV 3 is no longer ensured, for example in
the case of:
-
Visible damages of the housing or the measuring leads,
01/ 2019
key. A flashing triangle
Remedy
The electronic components of the BENNING PV 3 have reached
the maximum admissible temperature. Disconnect the BENNING
PV 3 from the object to be measured and let it cool down.
The DC short-circuit current exceeds the maximum value of 40 A.
Measurement has been stopped.
The DC open circuit voltage has exceeded the maximum value of
1500 V. The measurement has been stopped.
The BENNING PV 3 is not correctly calibrated, please return
the instrument to an authorized service center, see chapter 9.5
"Calibration".
Please return the BENNING PV 3 to an authorized service center,
see chapter 9.5 "Calibration" for the address.
Please return the BENNING PV 3 to an authorized service center,
see chapter 9.5 "Calibration" for the address.
Please return the BENNING PV 3 to an authorized service center,
see chapter 9.5 "Calibration" for the address.
Please return the BENNING PV 3 to an authorized service center,
see chapter 9.5 "Calibration" for the address.
Immediately disconnect the BENNING PV 3 from the PV genera-
tor!
Please return the BENNING PV 3 to an authorized service center,
see chapter 9.5 "Calibration" for the address.
Please return the BENNING PV 3 to an authorized service center,
see chapter 9.5 "Calibration" for the address.
Please return the BENNING PV 3 to an authorized service center,
see chapter 9.6 "Calibration" for the address.
BENNING PV 3
key of the BENNING SUN 2 and
above the
key shows that the radio transmis-