Herunterladen Inhalt Inhalt Diese Seite drucken

Environment Conditions; Electrical Specifications; Pv Module/ Pv String/ Pv Field, Open-Circuit Voltage (Vo/C); Pv Module/ Pv String/ Pv Field, Short-Circuit Current (Is/C) - Benning PV 3 Bedienungsanleitung

Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

reduced in order to allow the BENNING PV 3 to cool down. Do not leave the BENNING PV 3 attached to
a hazardous voltage for extended periods of time or while waiting for the BENNING PV 3 to cool down.
The BENNING PV 3 automatically tests connected PV modules, PV strings or PV fields. All measuring
results are displayed on the large LC display.
-
Appliance dimensions:
-
Appliance weight:
-
Power supply:
-
Interface:
-
Internal memory:
-
Display:
-
PC software:
-
Radio range to BENNING SUN 2: 30 m in open space, frequency: 433 MHz

6. Environment conditions

-
The BENNING PV 3 is intended for making measurements in dry environment.
-
Maximum barometric elevation for making measurements: 2000 m,
-
Over voltage category/ Siting category: IEC/ EN 61010-1 →1500 V for systems without a specified
measuring category,
-
Pollution Class 2,
-
Protection Class: IP 40 (DIN VDE 0470-1, IEC/ EN 60529) with the cover being open
IP 40 means: Protected against objects >1mm, (4 - first index). No protection against water, (0 - second
index).
IP 64 with the cover being closed
IP 64 means: Protection against access to dangerous parts and protection against solid impurities,
dustproof, (6 - first index). Splash proof, (4 - second index). Can also be used in case of precipitation.
-
EMC: IEC/ EN 61326-1,
-
Operating temperature and relative humidity: For operating temperature from 0 °C to 40 °C: non-
condensing
-
Storage temperature: The BENNING PV 3 can be stored at any temperature in the range from - 25 °C
to + 65 °C (relative humidity from 0 to 90 %). The battery should be taken out of the instrument for
storage.

7. Electrical specifications

Note: The measuring precision is specified as the sum of
-
a relative fraction of the measured value and
-
a number of digits (counting steps of the least significant digit).
This specified measuring precision is valid for temperatures in the range from 18 °C to 30 °C and relative
humidity less than 80 %.
7.1

PV module/ PV string/ PV field, open-circuit voltage (Vo/c)

Measuring range
5.0 V - 1500 V
7.2

PV module/ PV string/ PV field, short-circuit current (Is/c)

Measuring range
0.50 A - 40.00 A
(maximum power: 45 kW)

8. Measuring with the BENNING PV 3

8.1

Preparation for measuring

Operate and store the BENNING PV 3 only at the specified storage and operating temperatures conditions.
Do not permanently expose the device to sunlight.
-
Strong sources of interference in the vicinity of the BENNING PV 3 can lead to unstable readings and
measuring errors.
01/ 2019
(L x W x H) = 340 x 300 x 152 mm
5000 g
3 x 3.7 V rechargeable lithium-ion batteries
USB type B
up to 999 data records
LC display with background lighting
Download program BENNING Datalogger (CSV format)
Resolution
0.1 V
Resolution
0.01 A
BENNING PV 3
Measuring accuracy
± (0.5 % + 2 digits)
Measuring accuracy
± (1 % + 2 digits)
16

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading