When you have securely installed your satellite dish in the correct direction, connect the LNB to the
measuring instrument using a short cable (if possible only 1.5 m long). Tip: Do not fully tighten the satellite
dish mounting clip. This will enable you to still make fi ne adjustments to the position of the dish.
To switch on the measuring instrument, press the
appear.
V1.0Ka-21
Battery
Searching

OPERATING MENU

MSK 115/S2 keypad. All functions of the measuring instrument can
be controlled using these buttons.
button once. The animated Kathrein logo will
The next screen shows the measuring instrument data, including
the model, version, satellite list loaded and the battery charge
level in percent.
Use the
and
until the required satellite is displayed.
Rotate the satellite dish in the general direction of the satellite
you are looking for and slowly search the sky. After each scan,
change the height. As you search the sky and pass each
satellite, the scale value on the measuring instrument and the
beep frequency change.
As soon as you have located your satellite, the measuring
instrument tone changes and it shows "Found" on the display.
A locked carrier is indicated by a closed padlock.
To obtain the highest possible RF and MER values, you must
set the optimum values for your chosen satellite by fi ne tuning
the azimuth, elevation and polarisation. Carefully tighten the
securing screws (please observe the technical documentation
enclosed with the satellite refl ector) whilst monitoring the display
to achieve the best reception quality.
Use the
button to switch the display from MER to MER (linear)
and to BER.
buttons to scroll through the available satellites